Cross Technologies 3116-22-23 Скачать руководство пользователя страница 1

Instruction Manual

           

Model 3116-22-23#  

 Two Channel Downconverter  

April 2016,  Rev. 0   

MENU

EXECUTE

MODEL 3116

C

ROSS 

T

ECHNOLOGIES INC.

CH1 G=+25.5 REF=

CH2 G=+25.5 AUTO-E

REMOTE

ALARM 

POWER

DOWNCONVERTER

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment. Printed in USA.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment 
model number, equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

Содержание 3116-22-23

Страница 1: ... Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll F...

Страница 2: ...pment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer...

Страница 3: ...e stays in external if the external level is 3 dBm 3 dB It is powered by a 100 240 10 VAC power supply and is in a 1 3 4 X 19 X 14 rack mount chassis MENU EXECUTE MODEL 3116 CROSS TECHNOLOGIES INC CH1 G 25 5 REF CH2 G 25 5 AUTO E REMOTE ALARM POWER DOWNCONVERTER FRONT PANEL 3116 22 23 AC GND J20 J2 J1 J10 MONITOR AND CONTROL 1 5 2 3 4 6 7 8 9 RF IN RF OUT J18 J3 10 MHz REF OUTPUT 10 MHz EXT REF IN...

Страница 4: ...mage Rejection 35 dB 2 dB Gain Max Fc 19 inch Standard Chassis 1 75 high X 17 0 deep Size DB9 NO or NC Contact Closure on Alarm Alarm Connector BNC female 75Ω works with 50 or 75 ohms 10 MHz Connectors Other 100 240 10 VAC 47 63 Hz 25 watts maximum Power BNC female 50Ω Other Options available RF In RF Out Connector RS232C RS485 422 9600 baud Ethernet Optional Power Alarm Remote Controls Indicators...

Страница 5: ...0Ω SMA RF In 50Ω SMA RF Out Connector Options Additional Connector Options See Table 2 2 PG 10 Available Options 0 to 50 degrees C Operation W31 Remote M C Ethernet Options Ethernet with SNMP and MIB Interface W18 Ethernet with Direct TCP IP Interface Ethernet with Web Browser Interface W28 W8 ...

Страница 6: ...anel DB 9 male J10 Pinouts RS 232C 422 485 Pinouts RS 232C 422 485 Pin Function 1 Rx 2 Rx RS 232C 3 Tx RS 232C 4 Tx 5 GND 6 Alarm Relay Common 7 Alarm Relay Normally Open 8 Not Used 9 Alarm Relay Normally Closed 3116 22 23 Manual Rev 0 Page 6 04 14 16 Female DB 9 PC Com Port Male DB 9 2 1 3 4 5 6 7 8 9 2 1 3 4 5 6 7 8 9 M C Cable Diagram Cross Technologies Frequency Converters and Frequency Source...

Страница 7: ...t Channel 2 Gain aaSH Returns aaSHxxx where aa unit address range 00 to 31 only used if interface is RS485 otherwise omit H command code xxx Channel 2 s Gain in 0 5 dB The unit will append the character if the command is sucessfully processed Get Reference Mode aaSE Returns aaSEx where aa unit address range 00 to 31 only used if interface is RS485 otherwise omit E command code x 0 for Internal 1 f...

Страница 8: ...interface is RS485 otherwise omit G command code xxx desired gain in 0 5 dB steps omit the decimal point Range 50 to 350 5 0 to 35 0 in 0 5 dB steps example CG155 Will set Channel 1 s gain to 15 5 dB The unit will reply with the character if the command is sucessfully processed Set Channel 2 Gain aaCHxxx where aa unit address range 00 to 31 only used if interface is RS485 otherwise omit H command ...

Страница 9: ...wer supply and housed in a 1 3 4 X 19 X 14 rack mount chassis The 3116 22 23 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 3116 22 23 is assembled POWER SUPPLY FIGURE 2 0 3116 22 23 Mechanical Assembly 3116 22 23 Manual Rev 0 Page 9 04 14 16 ...

Страница 10: ...y Normally Closed TABLE 2 2 2 2 2 Connector Optio ons Options Option RF L Band N 50Ω Type N 75Ω BNC NF 50Ω Type N 75Ω Type N NN 50Ω Type N 50Ω Type N S7 50Ω SMA 75Ω BNC SF 50Ω SMA 75Ω Type N SN 50Ω SMA 50Ω Type N SS 50Ω SMA 50Ω SMA Remote Serial Interface Interface DB 9 Male Protocol RS 232C RS 232C 422 485 Option Q 9600 baud rate no parity 8 data bits 1 start bit 1 stop bit 2 3 Front Panel Contro...

Страница 11: ... input level provided See Section 2 5 Menu Settings 5 Be sure DS2 green DC Power is on and DS6 red Alarm is off Figure 2 2 6 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and is inserted in the far slot in the drawer below the AC input as shown in Figure 2 3 There is a spare fuse in the near slot If a fuse continues to open the power supply is most likely defective AC Fuse 2 amp slow b...

Страница 12: ...dress Save Menu When R is selected from any above menu or at the end Alarm indications appear on the LEDs see Figure 2 2 All program changes must start with the operation of the Menu Execute switch and must also end with the operation of the Menu Execute switch verified by the Save Settings Menu If this sequence is not followed none of the changes will take effect If programming is initiated and n...

Страница 13: ...r any changes the operator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switch 2 Horizontal Switch This switch is mounted so its movement is horizontal and moves the display cursor left or right 3 Vertical Switch This switch is mounted so its movement is ve...

Страница 14: ... BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS WINDOW DO NOT SET A GAIN THAT WOULD EXCEED 0 dBm OR HAVE LESS THAN 20 dBm OUTPUT LEVEL Press the Up Down switch to change the gain in 0 5 1 or 10 dB steps and then push the Menu Execute switch to get to the Save Settings Menu GAIN 17 5 R When the display indicates the value desired you can push the Menu Execute switch to the next item OR you c...

Страница 15: ...does not meet the unit s specified parameters then the unit will not function properly The External Reference is present on the Reference Output connector J18 Auto Mode The unit defaults to the External 10 MHz Reference as long as the level meets the 3dBm 3dB specification REF AUTO E appears on the front panel display where the E indicates that the unit is using the External 10 MHz Reference The E...

Страница 16: ... Remote Interface Menu 6 Set RS485 Address Save When go to end SCROLL SCROLL PUSH BUTTON SCROLL SCROLL PUSH BUTTON R R R SCROLL SCROLL PUSH BUTTON CH1 GAIN 15 5 CH2 Gain 15 5 REF MODE AUTO INTERFACE RS232 RS485 ADDRESS 0 R R SAVE SETTINGS Y N SCROLL SCROLL PUSH BUTTON SCROLL SCROLL PUSH BUTTON REMOTE ON R SCROLL SCROLL PUSH BUTTON IP Addr 192 168 123 002 ON POWER UP 1 ON POWER UP 2 FIGURE 2 4 Menu...

Страница 17: ...fe operation of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring Appropriate consideration of equipment name plate rating should be used when addressing this co...

Страница 18: ... INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 3116 22 23 Manual Rev 0 Page 18 04 14 16 ...