background image

2.4  Installation / Operation

2.4.2  Installing and Operating the 2117-8485 Downconverter

1.)  Connect -20 dBm to 0 dBm signal 8.4 to 8.5 GHz, RF1 INPUT, J102 (Figure 2.1).
2.)  Connect RF1 OUT, J101 to the external equipment.

3.) Connect 100-240 

± 10% 

VAC, 47 - 63 Hz to AC connector on the back panel.

4.)  Be sure DS1 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2).
5.)  Select either INT (for internal 10MHz ref), AUTO (for internal 10MHz ref UNLESS a external 

10MHz, 0 dBm signal is connected to J2), or EXT (for external 10MHz, 0 dBm ref that is inserted 
at J2) on rear panel switch S1 (Figure 2.1).

6.)  If EXT is selected or AUTO is selected and there is a 10MHz, 0 dBm signal at J2, check that DS3 

(yellow, Ext 10 MHz) is on (Figure 2.2).

7.)  Check that a 10MHz, 0 dBm ±3 dB signal is present at the 10 MHz REF OUTPUT (J8) 

(Figure 2.1).

8.)  AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in 

the drawer below the AC input as shown in Figure 2.3. There is a spare fuse in the near slot. If a 
fuse continues to open, the power supply is most likely defective

2.4.3 Installing and Operating the 2117-8485 Upconverter

1. Connect  a -40 dBm to -20 dBm signal 1.8 to 1.9 GHz, RF2 IN, J111 (Figure 2.1).
2. Connect 1.8 - 1.9 GHz to RF2 OUTPUT, J112, to the external equipment.
3. Connect 100-240 ±10% VAC, 47 - 63 Hz to AC connector on the back panel.
4. Be sure DS1 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2).
5. Select either INT (for internal 10MHz ref), AUTO (for internal 10MHz ref UNLESS a external 10MHz, 

3 dBm signal is connected to J2), or EXT (for external 10MHz, 3 dBm ref that is inserted at J2) on rear 
panel switch S1 (Figure 2.1).

6. If EXT is selected or AUTO is selected and there is a 10MHz, 3 dBm signal at J2, check that DS3 

(yellow, Ext 10MHZ) is on (Figure 2.2).

7. Check that a 10MHz, 3 dBm ±3 dB signal is present at the 10MHZ REF OUTPUT (J8) (Figure 2.1).
8. AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the 

drawer below the AC input as shown in Figure 2.3. There is a spare fuse in the near slot. If a fuse 
continues to open, the power supply is most likely defective.

2117-8485 Manual 

 

             Page 8

    

        11/14/19

Содержание 2117-8485

Страница 1: ...oduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment mod...

Страница 2: ...echnologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be li...

Страница 3: ...l is connected to the external reference input The 2117 is powered by a 100 240 10 VAC power supply and in a 1 3 4 X 19 X 19 rack mount chassis MODEL 2117 CROSS TECHNOLOGIES INC EXT 10MHZ POWER ALARM...

Страница 4: ...band 1 5 dB 1 5 dB Frequency Resp 40 MHz 0 5 dB 0 5 dB Frequency Sense non inverting non inverting LO Characteristics LO Frequency Downconverter 6 90 GHz Upconverter 6 60 GHz Frequency Accuracy 0 01...

Страница 5: ...ply provides power for the assemblies The 2117 8485 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2117 8485 is assembled 1 PS IN PIN 1 12 VDC PIN 2 5 VDC PIN 3...

Страница 6: ...ts external 10MHz reference from J2 J2 J101 J111 UPCON J112 J111 1 8 to 1 9 BNC 40 to 20 RF2 IN RF2 OUT J11 RF1 IN DOWNCON J102 RF1 OUT EXT REF IN RF OUT AC AC INPUT 100 240 VAC 47 60 Hz Uses 2 amp Sl...

Страница 7: ...s FIGURE 2 3 2117 8485 DC1 Pinouts TABLE 2 2 Available Options P48 48 VDC Nominal 36 72 VDC 2 5A max R Redundant AC Power Supply Available Connector Options NF 50 N Type RF 75 F Type L Band N 50 N Ty...

Страница 8: ...se in the near slot If a fuse continues to open the power supply is most likely defective 2 4 3 Installing and Operating the 2117 8485 Upconverter 1 Connect a 40 dBm to 20 dBm signal 1 8 to 1 9 GHz RF...

Страница 9: ...ration of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit a...

Страница 10: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2117 8485 Manual Page 10 1...

Отзывы: