1.2 Technical Characteristics
2116-300-1600 Manual
Page 4
5/24/21
±2.0 dB, 1100 - 2100 MHz out; ± 0.5 dB, 40 MHz BW
Frequency Response
Channel Characteristics
LO Characteristics
± 0.01 ppm maximum over temp internal reference; external reference input
Frequency Accuracy
Non-inverting
Frequency Sense
< -55 dBC for two carriers at Fc +/-2 MHZ, each at -10 dBm out
Intermodulation
<-50 dBm (0.5-1.1 GHz and 2.1-3.3 GHz Out)
Spurious, Out of Band
SIGNAL RELATED <-55 dBC in band, -5 dBm out; SIGNAL INDEPENDENT,<-60 dBm
Spurious, Inband
3 dBm, ± 3 dB, 75 ohms, External In or Internal Out
10 MHz Level
28.9 GHz
LO Frequency
> 55 dB, minimum
Image Rejection
+ 20 dB ± 2 dB at Fc
Gain
BNC (female), 50
Ω
(designated L-Band)
RF Out Connector
Other
100-24 ±10% VAC, 47-63 Hz, 25 watts maximum
Power
19 inch, Standard Chassis 1.75” high X 14.0” deep
Size
DB9 - NO or NC Contact Closure on Alarm
Alarm Connector
BNC (female), 75
Ω
Connector; Works with 50
Ω
or 75
Ω
10 MHz Connectors
2.92 mm (female), 50
Ω
RF In Connector
-110
-90
-80
-70
-60
1MHz
100kHz
10kHz
1kHz
100 MHz
dBC/Hz
Phase Noise @ F (Hz) >
Yellow LED, Indicates External 10 MHz Reference Selected
External 10 MHz
Controls, Indicators
Green LED
Power
Selects Internal or External 10 MHz (Rear Panel DP3T Switch)
INT / AUTO / EXT Switch
Red LED, External Contact Closure
PLL Alarm
TABLE 1.1
2116-300-1600 Block Downconverter Specifications*
-45 to -25 dBm
Input Level Range
12 dB maximum gain
Noise Figure, Maximum
-15 dBm
Input 1dB Compression
30.0 to 31.0 GHz
Frequency
+5 dBm
Output 1 dB Compression
-25 to -5 dBm
Output Level Range
Output Characteristics (designated L-Band)
Input Characteristics (RF)
1100 to 2100 GHz
Frequency
50
Ω
/ 14 dB
Impedance / Return Loss
50
Ω
/ 14 dB
Impedance / Return Loss
Available Connector Options
50
Ω
2.92 (RF), 50
Ω
sma (L-Band)
- 29S
50
Ω
2.92 (RF), 50
Ω
N-Type (L-Band)
- 29N
50
Ω
2.92 (RF), 75
Ω
BNC (L-Band)
- 297
*+10 to +40 degrees C; Specifications subject to change without notice. © 2021 Cross Technologies, Inc.