2.2  Rear Panel Input/Output Signals  
Figure 2.1 shows the input and output connectors on the rear panel.

1

5 2

3

4

6

7

8

9

AC

GND

J8

J2

EXT 10MHZ

RF INPUT

INPUT

10MHZ REF

OUTPUT

INT

EXT

AUTO

S1

J1

L-BAND

OUTPUT

J101

J11

ALARM

AC INPUT 
100-240 ±10%VAC, 47-63 HZ
Uses 2 amp Slow Blo, 
5mm fuse

S1 - 10MHZ SWITCH
3-position switch. INT selects internal 10MHz ref. 
AUTO selects internal 10MHz ref, unless a 3dBm 
±3dB 10MHz signal is inserted on J2.
EXT selects external 10MHz ref from J2.

J101 - RF INPUT
SMA (female) 50 

 

11.7 to 12.2 GHz 
-35 dBm max input signal 
See Table 2.2 for other 
connector options.

J8 - 10MHZ REF OUTPUT
BNC (female) 75 

. Outputs currently 

selected 10MHz ref signal (3 dBm ±3 dB).

J1 - L-BAND OUTPUT
BNC (female) 50 

. 0.95 to 2.00 GHz, 

0 dBm max input signal. See Table 2.2 
for other connector options.

J2 - EXT 10MHZ INPUT
BNC (female) 75 

. Insert external 

10MHz reference here (3 dBm ± 3 dB).

J11 - ALARM
DB9 (female) connector. 
See Table 2.1. 

 

FIGURE 2.1   2116-116 Rear Panel I/O

s

TABLE 2.1 JJ11 

TABLE 2.1 J11 Pinouts (DB9)

Pin

Function

1

Not  Used

2

Not  Used

3

Not  Used

4

Not  Used

5

GND

6

Alarm Relay: Common

7

Alarm Relay: Normally Open

8

Not  Used

9

Alarm Relay: Normally Closed

TABLE  2.2 Connector  Optionns

Option

s

Option

RF

L-Band

STD

SMA, 50

BNC, 50

M

Type N, 50

BNC, 50

N

Type N, 50

BNC, 75

NF

Type N, 50

Type F, 75

NN

Type N, 50

Type N, 50

S7

SMA, 50

BNC, 75

SF

SMA, 50

Type F, 75

SN

SMA, 50

Type N, 50

SS

SMA, 50

SMA, 50

2.3  Front Panel Indicators 
Figure 2.2 shows the front panel indicators.

DS2 - ALARM LED
Lights RED when PLL 
comes out of lock.

DS1 - POWER LED A
Lights GREEN when DC voltage is 
present from AC power supply.

DS3 - EXT 10MHZ LED
Lights YELLOW when external 
10MHz reference is active.

POWER

EXT

10MHZ ALARM

FIGURE 2.2     2116-116 Front Panel Controls and Indicators

2116-116 Manual

 

 

                    Page 6

    

       06/231/10

Содержание 2116-116

Страница 1: ...roduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment mo...

Страница 2: ...nologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liabl...

Страница 3: ...ence is used and in the AUTO position the internal reference is used unless a 3 dBm 3 dB 10MHz reference signal is connected to the external reference input The 2116 is powered by a 100 240 10 VAC pow...

Страница 4: ...ut Frequency Response 1 5 dB 0 95 to 1 45 GHz out 0 5 dB 40 MHz BW Frequency Sense Non inverting LO Characteristics LO Frequency 10 75 GHz Frequency Accuracy 0 01 ppm max over temp internal reference...

Страница 5: ...assemblies The 2116 116 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2116 116 is assembled 1 PS IN PIN 1 12 VDC PIN 2 5 VDC PIN 3 5 VDC PIN 4 GROUND PIN 5 GRO...

Страница 6: ...tions J2 EXT 10MHZ INPUT BNC female 75 Insert external 10MHz reference here 3 dBm 3 dB J11 ALARM DB9 female connector See Table 2 1 FIGURE 2 1 2116 116 Rear Panel I O s TABLE 2 1 J J11 TABLE 2 1 J11 P...

Страница 7: ...panel switch S1 Figure 2 1 6 If EXT is selected or AUTO is selected and there is a 10MHz 3 dBm signal at J2 check that DS3 yellow Ext 10MHZ is on Figure 2 2 7 Check that a 10MHz 3 dBm 3 dB signal is...

Страница 8: ...he equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effec...

Страница 9: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2010 Printed in USA 2116 116 Manual...

Отзывы: