background image

Instruction Manual

                         

 

Model 2099-10 

10MHz Reference 

April 2019,   Rev. E 

POWER OVEN

MODEL 2099

FREQUENCY SOURCE

C

ROSS

 T

ECHNOLOGIES INC.

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment.

                

When ordering parts from Cross Technologies, Inc., be sure to include the equipment 
model number, equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

Содержание 2099

Страница 1: ...d or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model nu...

Страница 2: ...s Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for a...

Страница 3: ...BNC female A relay contact closure or open indicates when the oscillator oven is stabilized Powered by a 100 240 10 VAC power supply 1 3 4 X 19 X 14 rack mount chassis POWER OVEN MODEL 2099 FREQUENCY...

Страница 4: ...justment 0 1 ppm Oscillator Phase Noise 160 155 140 110 10kHz 1kHz 100Hz 10Hz dBC Hz Phase Noise Freq Controls Indicators Power Green LED Oven Warm Up Yellow LED External contact closure No contact cl...

Страница 5: ...14 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2099 10 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2099 10...

Страница 6: ...0 Rear Panel Outputs 1 6 2 3 4 5 7 8 9 TABLE 2 1 J1 19 TABLE 2 1 J19 Pinouts DB9 Pin Function 1 Not Used 2 Not Used 3 Not Used 4 Not Used 5 GND 6 Alarm Relay Common 7 Alarm Relay Open ALARM 8 Not Used...

Страница 7: ...M connector J19 to occur to insure that the oscillator oven is stabilized 5 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and is inserted in the far slot in the drawer below the AC input a...

Страница 8: ...equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 9: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2099 10 Manual Rev E...