2.4  Installation / Operation

2.4.1  Installing and Operating the 2083-2215, Frequency Translator Section

1. Connect  a -30 dBm to -10 dBm signal to IN, J4 (Figure 2.1)
2. Connect the OUT, J5, to the external equipment
3. Connect 100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel.
4. Set the desired output frequency band (See Section 2.5 Menu Settings).
5. Set the composite input level (See Section 2.5 Menu Settings).
6. Set the gain for 0 to +20 dB. Make sure the output stays within -30 to -10 dBm with the gain selected 

and the input level provided. The firmware will prevent setting gain and input level outside this range. 
(See Section 2.5 Menu Settings).

7. Be sure DS6 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2).
8. AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the 

drawer below the AC input as shown in Figure 2.3. There is a spare fuse in the near slot. If a fuse 
continues to open, the power supply is most likely defective.

AC Fuse - 2 amp slow blow (Type T), 
5 mm X 20 mm

FUSE DRAWER

SPARE FUSE

~

INPUT

100-240± 10%VAC

47-63 Hz

2A MAX

FUSE

TYPE T 2A GDC

250 VOLT

FOR 100 - 240 V~

~

FIGURE 2.3    Fuse Location and Spare Fuse

2083-2215 Manual- Rev B

 

            Page 8

    

             9/08/09

Содержание 2083-2215

Страница 1: ...plicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment...

Страница 2: ...gies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable fo...

Страница 3: ...e Front panel LEDs light when DC power is applied green and when a PLL alarm occurs red The 2083 2215 is powered by a 100 240 10 VAC power supply and housed in a 1 75 X 19 X 16 1RU chassis MODEL 2083...

Страница 4: ...nslates to 0 95 GHz Intermodulation 50 dBC for two carriers each at 13 dBm out Spurious Response 40 dBC for 1 725 2 175 GHz input to 0 95 to 1 4 GHz out 0 95 1 4 GHz Feedthru 30 dBC min 40 dBC goal 1...

Страница 5: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 6: ...by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2083 2215 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 208...

Страница 7: ...t see Table 2 2 FIGURE 2 1 2083 2215 Rear Panel I O s TABLE 2 1 J J10 TABLE 2 1 J10 Pinouts Pin Function 1 Rx 2 Rx RS 232C 3 Tx RS 232C 4 Tx 5 GND 6 Alarm Relay Common 7 Alarm Relay Normally Open 8 No...

Страница 8: ...cted and the input level provided The firmware will prevent setting gain and input level outside this range See Section 2 5 Menu Settings 7 Be sure DS6 green DC Power is on and DS2 red Alarm is off Fi...

Страница 9: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2083 2215 Manual Rev...

Отзывы: