![Cross Technologies 2017-0923 370 Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/cross-technologies/2017-0923-370-series/2017-0923-370-series_instruction-manual_2688745013.webp)
Option E1
Units with option E1 operate as described above but also have an Auto mode. When in auto mode the unit will
detect and select the external 10 MHz signal if it is present and at least +3 dBm. If the external 10 MHz signal
falls below 1 dBm (+/- 1 dB) the unit will automatically switch to the internal 10 MHz reference. The reference
out connector (J14) provides a buffered rendition of the selected 10 MHz signal at +3 dBm, +/- 3 dB.
Units with option E1 do not have the ability to insert a buffered rendition of the selected 10 MHz signal on the
center pin of the (RF) connector.
2017-0923#-370
Page 13
02/15/22