Instruction Manual

                         

Model 2017-03A

    Up/Downconverter

July 2019,   Rev. I

MENU

EXECUTE

MODEL 2017

C

ROSS 

T

ECHNOLOGIES INC.

U  F=1525     G=+00
D  F=1525     G=+25

MUTE

UPCONVERTER

DOWNCONVERTER

REMOTE

ALARM POWER

ALARM

UP/DOWNCONVERTER

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be 

reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating 

the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, 

equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

Содержание 2017-03A

Страница 1: ...Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies In...

Страница 2: ...to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies...

Страница 3: ...d gain settings appear on the LCD display Connectors are BNC female for IF and the optional external reference input and output and Type F female for RF A high stability 0 01ppm option is also availab...

Страница 4: ...baud RS485 option Q Other RF Connectors Type F female see Table 2 2 for connector options IF Connectors BNC female see Table 2 2 for connector options 10MHz Connectors BNC female 50 75 option E Alarm...

Страница 5: ...Female DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 male J10 Pinouts RS 232C 422...

Страница 6: ...ers standard 7 characters Option X ddd Tx gain 10 to 30 ee Rx gain 00 to 50 ff Tx input level 10 to 40 10 to 40 dBm L 0 non inverted Receiver L 1 inverted M 0 Receiver synth alarm N 0 Transmitter synt...

Страница 7: ...cters Range 10 to 40 10 to 40 dBm Set Receiver Frequency aaC2xxxx where xxxx 4 characters standard 7 characters Option X Range 0950 to 1525 MHz Set Transmit Gain aaC3xxxx where xxxx 2 or 3 characters...

Страница 8: ...erloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring App...

Страница 9: ...y 16 inch deep chassis A switching 12 5 24 VDC power supply provides power for the assemblies The 2017 03A can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2017 0...

Страница 10: ...e places 24 VDC 2 5 amp max on the RF OUT J5 center pin F1 LNB FUSE option L 0 5A Fast Blo 1 4 Fuse installing fuse places 24 VDC 0 4 Amps max on the RF IN J2 center pin LNB FUSE F1 DOWNCONVERTER UPCO...

Страница 11: ...2 3 DC1 Pinouts Pin Function 1 Minus DC input 2 NC 3 Plus DC input 4 NC Shell Ground Remote Serial Interface Interface DB 9 Male Protocol RS 232C RS 485 option Q 9600 baud no parity 8 data bits 1 sta...

Страница 12: ...presence of DC power DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode Does not function in the no...

Страница 13: ...ter Section 1 Connect a 60 dBm to 10 dBm signal to RF In J2 Figure 2 1 2 Connect the IF OUT J1 to the external equipment 3 Connect 100 240 10 VAC 47 63 Hz to AC on the back panel 4 Set the desired inp...

Страница 14: ...p slow blow Type T 5 mm X 20 mm FUSE DRAWER SPARE FUSE INPUT 100 240 10 VAC 47 63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 240 V Figure 2 3 Fuse Location and Spare Fuse 2017 03A Manual Rev I Page...

Страница 15: ...Out option E Menu 10 Downconverter Reference Out option E Menu 11 Set RS 485 mode option Q Menu 12 Set RS 485 address option Q Menu 13 View PCB Temperature option T Menu 14 View LNB and or SSPB Curre...

Страница 16: ...rator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switch...

Страница 17: ...gle the display to UP F 145 0 R By using the horizontal rocker switch the cursor can be moved left or right UP F 1450 R NOTE CHANGES DO NOT TAKE PLACE ON FREQUENCY UNTIL YOU GO TO THE SAVE MENU AND IN...

Страница 18: ...y is for changing the upconverter input level This is an important setting to optimize spurious and should be made as accurately as possible UP INLVL 20 R Pressing the Up Down switch down will toggle...

Страница 19: ...ssing the Up Down switch down will toggle the display digit selected until you have the desired gain NOTE THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS HOWEVER THE VALUE WILL NOT BE STORED UNTIL...

Страница 20: ...ect Upconverter Reference Out option E Menu 10 Select Downconverter Reference Out option E Menu 11 Reference Offset option E Menu 12 Set Remote Mode option Q Menu 13 Set RS 485 Address option Q Menu 1...

Страница 21: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2017 03A Manual Rev I...

Отзывы: