(Continued from page 8)...
Table 1.2 2016-8085 Commands, (continued)...
Table 1.2 2016-8085 Commands, (continued)...
Table 1.2 2016-8085 Commands, (continued)...
Command
Syntax*
Description
Set Remote Off
{aaCR0}
Where:
• aa = unit address, range = 00 to 31, only used if
interface is RS485, otherwise omit.
• R = command code
• 0, ascii number zero.
example: {CR0}
Will disable the unit's serial M&C port.
The unit will reply with the '>' character if the
command is sucessfully processed.
(Note: this command only affects the serial M&C port,
the ethernet port is always on and will not be affected).
Set Remote On
#
Just the ascii pound sign, (0x23)
Will enable the unit's serial M&C port.
The unit will reply with the '>' character if
the command is sucessfully processed.
(Note: this command only affects the serial M&C port,
the ethernet port is always on and will not be affected).
2016-8085 Manual_Rev. 0 Page 9 05/10/22