Instruction Manual

                   

Model 2005-10     

Test Upconverter     

April 2009   Rev B            

DC ALARM

C

ROSS 

T

ECHNOLOGIES, INC.

2005 TEST CONVERTER

C

KU

LO

70 140

IF

FREQUENCY

GHz

1MHz

10MHz

100MHz

C

ROSS 

T

ECHNOLOGIES, INC.

DC POWER

RF

IF

GAIN

HI LOW

J1

J3

J2

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment 
model number, equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

Содержание 2005-10

Страница 1: ...ary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technolo...

Страница 2: ...ent to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technolog...

Страница 3: ...zed LO Front panel LEDs light when DC power is applied green and when a PLL alarm occurs red The mixer output is applied to the output attenuator providing a nominal gain of 10 dB high gain or 30 dB l...

Страница 4: ...OT FILTERED Frequency Response 2 dB 2 0 2 5 GHz 0 5 dB any 10MHz increment Synthesizer Characteristics Frequency Accuracy 25 kHz max Frequency Step 1 0 MHz minimum 100 90 75 70 70 1MHz 100kHz 10kHz 1k...

Страница 5: ...70 140 70 or 140 MHz in GHz DS2 ALARM LED Lights red when PLL comes out of lock SW5 IF SWITCH Slide switch selects 70 or 140 MHz IF in DC ALARM CROSS TECHNOLOGIES INC 2005 TEST CONVERTER C KU LO 70 14...

Страница 6: ...SSEMBLY REAR PANEL WALL POWER SUPPLY P and P4 ONLY 2005 TEST CONVERTER CROSS TECHNOLOGIES INC DC 100MHz FREQUENCY 10MHz 1MHz GHz LO IF C KU 70 140 ALARM FIGURE 2 3 2005 Assembly Drawing 2 5 Installati...

Страница 7: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 8: ...HNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2005 10 Manual Rev B Page 8...