background image

2.0  Installation

2.1  Mechanical
The 2005 is packaged in an aluminum extrusion. The -R option is mounted on a 1 3/4” X 19”panel that can be 
mounted to a  rack using the 4 holes at  the ends.  Both units derive  +DC from the RF out center  conductor (+14 to 
+20 VDC) or the wall power supply (+15VDC unregulated). See Figure 2.3.

2.1.1  Cleaning Instructions 
Wipe the exterior with a dry, soft cloth. Use no detergent or cleaning chemicals. 

2.2  Front Panel Controls and Indicators
Figure 2.1 shows the controls and indicators located on the front panel. 

SW6 - LO SIDE SELECT
SPDT slide switch  selects high side (C) 
or low side (Ku) local oscillator. 

DS1 - DC POWER LED
Lights green when DC power 
is present

SW1 to SW4 - FREQ SELECT SWITCHES
BCD switches select the desired output frequency 
which is the Local Oscillator frequency - 70 ,  -140, 
+70,  or +140 MHz.

DS2 -   ALARM   LED
Lights red when PLL 
comes out of lock

SW5 - IF SELECT
SPDT slide switch  selects 
70 or 140 MHz IF in. 

   2005 TEST UPCONVERTER

 C

ROSS 

T

ECHNOLOGIES, INC.

DC

100MHz

FREQUENCY

10MHz 1MHz

GHz 

LO

IF

C

KU

70 140

ALARM

FIGURE 2.1      Front Panel Controls and Indicators

2.3  Rear Panel Inputs, Output, and Controls 
Figure 2.2 shows the inputs, outputs, and controls located on the rear panel of the 2005. 

J1 - IF   INPUT
The IF 70 or 140 MHz  
input . This is a 75

Ω

BNC input at -10 dBm 
max  level for LOW GAIN 
(-30 dB) and -30 dBm 
max level for HI GAIN (-
10 dB). The gain is 
selected by SW7.

J3 - DC POWER
The +15 VDC unregulated DC voltage 
from the wall power supply.

J2 - RF OUTPUT
The mixed RF output. 
This is an unfiltered 
output and contains 
mainly the LO- IF, LO, 
LO + IF, mixer products. 
This is a 75

Ω

, Type F, 

female connector.

GND                           +15

SW7 - GAIN SELECT SWITCH
Slide switch selects -10 dB high gain (HI) 
or -30 dB low gain (LOW) . 

DC POWER

RF OUT

IF IN

 GAIN

HI

LOW

J1

J3

J2

 C

ROSS 

T

ECHNOLOGIES, INC.

 +DC IN
 +15V, 600 ma

FIGURE 2.2      Rear Panel Inputs, Outputs, and Controls

2005-02/03 Manual, Rev. J

 Page 5  

  

               08/14/2019

Содержание 2005-02P4

Страница 1: ...in are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from...

Страница 2: ...pment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technol...

Страница 3: ...low phase noise these units are used to loop 70 or 140 MHz modulators to L band receivers in uplinks The 70 or 140 MHz carrier input is mixed with a synthesized local oscillator LO signal The output f...

Страница 4: ...quency Accuracy 25 kHz max Frequency Step 1 0 MHz minimum 80 10kHz 100 90 1MHz 100kHz dBC Hz Phase Noise Freq Controls L Band Frequency Selection BCD switches with direct readout LO Selection SPDT sli...

Страница 5: ...s red when PLL comes out of lock SW5 IF SELECT SPDT slide switch selects 70 or 140 MHz IF in 2005 TEST UPCONVERTER CROSS TECHNOLOGIES INC DC 100MHz FREQUENCY 10MHz 1MHz GHz LO IF C KU 70 140 ALARM FIG...

Страница 6: ...o install the PCB gently push the rear panel and PCB assembly completely into the extrusion Make sure the shield goes in the lower channel and the PCB in the next channel above that in the extrusion a...

Страница 7: ...d low side LO for Ku band Also note that there will be a spectrum inversion of the input IF modulation with the high side LO Although the 2005 02 operates over it s full 950 to 2050 MHz range with hig...

Страница 8: ...ution D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and...

Страница 9: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2005 02 03 Manual Rev...