2.3 Installation / Operation,
(continued from page 9)
12. The maximum total charge current of the Power Supply/Charger is 8 Amps. In the event that multiple
highly discharged batteries are installed and the total desired charging current is greater than 8 Amps, the
charger will disable charging on one or more batteries as needed (beginning with D, then C etc.) to keep
the charge current below 8 Amps. Charging of the disabled batteries will resume when the power load on
the charger allows.
2.4 Alarm Indications
TABLE 2.0 2000-16-3624 Power Supply/Battery Charger Alarm States
2.5 Connector - Side panel, DB-9 female
2000-16-3624 Manual_Rev.0
Page 10
09/17/15
Alarm Flashes Continuously
Thermal Shutdown (All Outputs Disabled)
Alarm Flashes three times then pauses (repeats)
Over Temperature Alarm (Charging Disabled)
Alarm Flashes twice then pauses (repeats)
Charging Voltage and/or Current Alarm
Alarm LED and +12V LED Flash Simultaneously
+12VDC Voltage and/or Current Alarm
Alarm LED and +24V LED Flash Simultaneously
+24VDC Voltage and/or Current Alarm
Primary Alarm Indications
TABLE 2.0 2000-16-3624 Power Supply/Battery Charger Alarm States
Ground (+12VDC Return)
9
Ground (+12VDC Return)
No Connection
No Connection
+12VDC
Function
Pin
8
7
6
5
+12VDC
4
No Connection
3
No Connection
2
No Connection
1
TABLE 2.1 +12VDC DB-9 Connector Pinouts