2.4
Operation
1. Set the on board controls as desired (Tables 2.0, 2.1, Figure 2.3).
2. Install the 1582-225L2 in the equipment rack.
3. Connect RF to the BNC connectors (J1, J2, J3, J4, J5, J6, J7, J8, J9, J10, J11, J12).
4. Connect to signals on the MONITORS AND CONTROLS (DB9 connectors), J16A & J16B,
as desired (see Figure 2.2, Table 2.1).
5. Connect power via two power cords to AC1 and AC2.
6. Manually switch between PRIMARY and BACK-UP and be sure switching occurs.
Check SW1 and SW2.
7. Switch to AUTO Alarm Switch 1 and note that automatic switching occurs. Remove alarm
to CHI and note that the output switches as desired. Push RESET if in LATCH mode.
Repeat for CH2.
AC Fuse - 2 amp slow blow (Type T),
5 mm X 20 mm
FUSE DRAWER
SPARE FUSE
~
INPUT
100-240± 10%VAC
47-63 Hz
2A MAX
FUSE
TYPE T 2A GDC
250 VOLT
FOR 100 - 240 V~
~
FIGURE 2.4 Fuse and Spare Fuse Locations
1582-225L2 Manual, Rev. A
Page 16