background image

MODEL 1200-07 IF AGC AMPLIFIER

1.0  General

1.1  Equipment Description
The 1200-07 IF Amplifier provides automatic gain control (AGC) for a 50 to 200 MHz IF signal.   It takes a 
-80 to 0 dBm input signal and automatically adjusts the gain for a -35 dBm ± 10 dB output. The 1200-07 has 
a band limiting lowpass filter. It also has capabilities to switch between automatic gain control (AGC) or 
manual gain control (MGC). A potentiometer on the rear panel allows for manual gain adjustment when in 
MGC mode. The IF in and out connectors are BNC female.  All circuitry is on a single PCB housed in a 1RU 
X 14” deep chassis. An internal switching power supply powers the unit with a 100-240 ±10% VAC, 47-63 
Hz input.  

 

REAR

FRONT

J1

MODEL 1200

AMPLIFIER

C

ROSS 

T

ECHNOLOGIES, INC.

POWER

IF

MONITOR

LEVEL

ADJUST

AC

GND

J109

IF 2

OUT

IF IN

J107

J106

IF 1

OUT

S5

AGC

MGC

MGC

ADJUST

R123

J104

AGC

VOLTAGE

FIGURE 1.1     Model 1200-07 Front and Rear Panels

IF 2

OUT

(J107)

IF MON

OUT

(J1)

IF 1

OUT

(J106)

S
P
L

I

T
T
E
R

IF
IN

(J109)

AGC

CONTROL

ATT

ATT

AGC

ATT

MGC

V

FIGURE 1.2     Model 1200-07 Block Diagram

1200-07 Manual_A

  

 

Page 3

    

                            09/13/10

Содержание 1200-07

Страница 1: ...ced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the e...

Страница 2: ...logies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable...

Страница 3: ...for manual gain adjustment when in MGC mode The IF in and out connectors are BNC female All circuitry is on a single PCB housed in a 1RU X 14 deep chassis An internal switching power supply powers the...

Страница 4: ...equency Response 1 0 dB 18 MHz Group Delay max 5 ns max 50 to 100 MHz Controls Indicators AGC MGC Switch Switches between Manual MGC or Automatic AGC Gain control MGC Potentiometer Adjusts gain in MGC...

Страница 5: ...high by 14 inch deep chassis An AC power supply provides 15VDC and 15VDC to the PCB The 1200 07 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 1200 07 is assem...

Страница 6: ...he output level when in Manual Gain Control MGC mode S5 MGC AGC SWITCH SPDT switch that selects either Manual Gain Control MGC or Automatic Gain Control AGC mode FIGURE 2 2 1200 07 Rear Panel I Os and...

Страница 7: ...ear panel potentiometer R123 for the desired gain Figure 2 2 8 Adjust output to desired level using front panel attenuator pot R3 Figure 2 3 Clockwise rotation provides increased output level full clo...

Страница 8: ...or J104 can be monitored to determine the approximate input level and corresponding gain in AGC as Table 2 2 shows TABLE 2 1 Approximate AGC Vo oltage Voltage vs Gain and Input Le evel Level AGC Volta...

Страница 9: ...he equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effe...

Страница 10: ...IES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 1200 07 Manual_A P...

Отзывы: