INTRODUCTION

Crosby CLAMP-CO beam clamps are below the hook lifting devices designed to provide
an efficient method for handling wide flange beam sections and plate girders. Always
follow the stated limitations discussed in this manual and shown on the product’s Warning
and Operating Procedure Labels.

Crosby Clamp-Co beam clamps have been safely and successfully used in the field for
over 30 years. Your safe use of our products depends on you. Please be responsible and
make sure all people using our products follow these simple rules:

1. 

Beam Clamps are used to the purpose for which they were designed.

2.  They are not loaded beyond their Working Load Limit.
3.  They are properly lubricated and maintained.
4.  They are inspected regularly and tested in accordance with the relevant statutory 

regulations.

5.  They are used by competent persons trained in their use.
6.  Beam Clamps are returned to the factory every two years for inspection, 

retesting and recertification.

As with all mechanical handling equipment, there is a degree of hazard involved with the
use of these beam clamps if not properly used. Failure to follow the appropriate safety
precautions and operating instructions may cause the load to slip or fall, and may result in
serious injury, death, or property damage.

GENERAL INFORMATION

Each Crosby Clamp-Co beam clamp is proof tested and certified prior to shipping. Beam
Clamps are proof tested to 200% of Working Load Limit.

Follow all requirements of laws, rules, and regulations applicable in your country pertaining
to lifting operations, ensuring all maintenance, testing, inspection and operator training
requirements are strictly adhered to.

Содержание Clamp-Co F-5

Страница 1: ...MANUAL Model Numbers F 5 F 15 F 25 F 35 NS 15 NS 25 NS 35 IMPORTANT Make certain all persons that may use inspect or maintain this equipment carefully read and understand this manual Retain this manual in permanent file ...

Страница 2: ... maintained 4 They are inspected regularly and tested in accordance with the relevant statutory regulations 5 They are used by competent persons trained in their use 6 Beam Clamps are returned to the factory every two years for inspection retesting and recertification As with all mechanical handling equipment there is a degree of hazard involved with the use of these beam clamps if not properly us...

Страница 3: ...een 212 F 100 C and 40 F 40 C For other temperatures and for use in hazardous environmental conditions consult The Crosby Group technicians WARNING Loads may disengage from clamp if proper procedures are not followed A falling load may cause serious injury or death The clamp shall not be loaded in excess of its rated load or handle any load for which it is not designed Never operate a damaged or m...

Страница 4: ... returning the clamp to the manufacturer when repairs are required Slowly lower the clamp onto the beam and center the clamp in line with the beam s center of gravity lengthwise See Figure 1 Use the handle to pull the tongs out if necessary and guide tongs under the beam flange See Figure 2 Make adjustments until the tongs are firmly gripping the beam flange and the clamp is in center with the bea...

Страница 5: ...ND MAINTENANCE A visual inspection for cracks wear gouges and deformation as part of a comprehensive documented inspection program should be conducted by trained personnel in compliance with the schedule in ANSI B30 20 Proper maintenance of the beam clamp includes a daily inspection and weekly lubrication There are labels attached to the clamp frame which provide required maintenance inspection an...

Страница 6: ... other moving and or load bearing parts Is restraining chain and grab hook locking arrangement functional Are the Working Load Limit Serial Numbers and Warning labels legible Have all inspections and maintenance been regularly recorded Does the Crosby Clamp Co product carry its original Identification Plate and Warning information If the identification plate has been damaged or removed the clamp s...

Страница 7: ...5 2 153 15 50 34 00 17 00 27 00 34 50 25 00 7 00 17 00 2 00 NS 15 2732018 15 7 17 5 2 153 15 50 34 00 17 00 27 00 34 50 25 00 7 00 17 00 2 00 F 25 2732027 25 16 24 1 3 290 23 00 48 00 22 25 36 00 53 00 37 25 16 00 24 00 3 00 NS 25 2732036 25 16 24 1 3 290 23 00 48 00 22 25 36 00 53 00 37 25 16 00 24 00 3 00 F 35 2732045 35 16 36 1 63 4 519 30 00 64 00 27 50 48 00 58 00 53 00 16 00 36 00 4 00 NS 35...

Страница 8: ...2801 Dawson Rd Tulsa OK 74110 P 918 834 4611 F 918 832 0940 www thecrosbygroup com crosbygroup thecrosbygroup com 9992279 07 31 14 ...

Отзывы: