CropX Deep Скачать руководство пользователя страница 8

This document and the information thereon are the property of CropX, and

 

may only be used for the purpose for which this document was supplied.

 

 

Uninstalling the Sensor

 

 

It is recommended to uninstall the sensors at the end of each 

season, by completing the following:

 

  

Bring the handle, the sensor head adapter, a 1/2 gallon of 
water and a shovel.

 

  

Using the app, click on the sensor you wish to uninstall and 
a path between you and the sensor will be displayed. Go to 
the sensor.

 

  

Ensure the soil is moist. It is recommended to wet the soil 
around the sensor both a day prior to uninstalling, and just 
before the uninstallation.

 

  

Connect the sensor head adapter to the handle.

 

  

Mount the sensor head adapter to the grooves on the top 
of the sensor head.

 

  

Mount the handle on the sensor head adapter socket tool 
and loosen it counterclockwise.

 

  

If you feel strong resistance from the sensor while trying to 
screw it out, pour water around the sensor area to soften 
the soil. You may use the shovel to dig around the sensor 
to further loosen the soil but make sure to keep a distance 
of at least a foot away from the sensor.

 

  

After removing the sensor, keep the sensor in a safe and 
dry place and charge it prior to the next installation.

 

 

**Note: In addition to the physical uninstallation of the 

sensor, it should also be deactivated from the App.

 

Содержание Deep

Страница 1: ...For more information please visit us online at www cropx com Sensor Installation Guide...

Страница 2: ...fers two sensor models CropX Pro Soil measurements at 8 18 20 cm 45cm see fig 1 below left CropX Deep Soil measurements at 8 18 36 20cm 45cm 90cm see fig 1 below right Each model is shipped with a mat...

Страница 3: ...3 CropX Installation Kit Contents Item Description Item image Drill bit Pro 0 7 X 21 6 18 x 550 mm Deep 1 02 X 45 2 26 x 1150 mm Handle Sensor head adapter CropX Sensor Installation Guide...

Страница 4: ...e add a new field sign at the first screen and following the instructions By clicking on one of the fields you ve created if no sensors are currently installed a link to install your sensor will appea...

Страница 5: ...ation in the field that best represents the crop between the plants in average plant density In a flat surface with no slope no ditch or cracked soil Away from the tractor and pivot wheel tracks In a...

Страница 6: ...he bit reaches the full depth Pour water slowly into the hole until it s full wait 5 minutes and then top off the hole with more water until it s full Wait 5 more minutes and if the soil is dry add mo...

Страница 7: ...ensor almost all the way down using the handle leaving a 1 finger gap between the ground level and the bottom of the sensor head Remove the sensor head adapter from the sensor Set the antenna extensio...

Страница 8: ...prior to uninstalling and just before the uninstallation Connect the sensor head adapter to the handle Mount the sensor head adapter to the grooves on the top of the sensor head Mount the handle on th...

Страница 9: ...port cable provided and connect to a certified UL CE USB power adapter Allow the sensor to fully charge for at least 10 hours until the light changes to green this may take up to 24 hours depending on...

Страница 10: ...ower Risk of explosion if battery replaced by an un authorized personnel Dispose used batteries according the local regulations 3 7V 10 4Ah 38 48Wh Two Li Ion battery pack Charging at 5VDC 2A max Envi...

Страница 11: ...permission of CropX Technologies Ltd the information contained herein is designed only for use with the CropX sensor CropX Technologies Ltd is not responsible for any use of this information as applie...

Страница 12: ...evision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate th...

Страница 13: ...13...

Отзывы: