System Maintenance
Chapter 6: System Maintenance
For optimum performanceand productivity, regular maintenance and services are required
to be carried out on the device. The following are recommended maintenance cycles and
details to be noted (Inappropriate handling not according to recommendation may affect
device performance and even damage the machine).Maintenance is divided into routine
maintenance and regular maintenance. The device must to be operated under
standardenvironment requirement as stated according in the
《
User Manual
》
.
Attention: Power must be turned off to ensure safety during maintenance.
Surface cleaning manners and precautions
:
While cleaning device surface, first used a vacuum cleaner to clean dusts on the machine
casings, seams and accumulated dusts on plate loading platform.
If the indoor air is dry and clean, and the machine is often being cleaned, just use dry cloth is
wipe and remove the dust from the surface;
For thoroughly cleaning, wipe with a damp cloth mixed with mild cleanser and clean with a
damp cloth with detergent until it is cleaned and dried.
Attention: Do not spill or leak water or detergent into the device, this could
causehazardous to operator or damage the machine.
Important: Strongly recommended that the following maintenance should be carried out by a trained
engineer or under the direction of a CRON qualified engineer.
6.1Device internal cleaning & inspection procedures
6.1.1Drum surface cleaning: After certain period of usage, plate pressing roller (mounting roller) and
drum surface will have accumulation of dusts and abrasions, that could cause damageson plate surface,
and/or affect the surface flatness during plate loading or mounting, it is necessary to clean up both the
roller and drum surface at any time if found dusty;
a)
For HDI600/HDI920 series, flip open the front cover of the device, and slide the whole hood
backward to rear of device until its limit position. Front upper drum section is now fully visible,
you can observe the plate pressing roller (mounting roller) and drum surface conditions and its
mechanism components, please use dry cloth to clean and wipe these area if found dusty.
Содержание HDI-1600
Страница 2: ...2 55 Revision History Version A1 Date 2017 11 12 Version A2 Date 2018 4 19 ...
Страница 24: ...Operation Instructions 24 55 Note Please refer to the Laboo HDI User s Manual for detail software operation ...
Страница 46: ...Consumables Parts and Spare Parts 46 55 5 Transmission Densitometer 6 Film Ruler 1 5m ...
Страница 52: ...Appendix 52 55 ...