Cristófoli  Vacuum  Pumps  are  individually  monitored  according  to  internal  test  and 

manufacturing patterns approved by Cristófoli’s quality control.

QUALITY CONTROL 

 

If there’s any problem with your equipment, at first, see the topic “

Troubleshooting

” (Page. 

12), if the problem persists, contact your 

local dealer 

for an evaluation and possible repair of 

your  equipment.  It  will  be  also  necessary  to  have  the  original  invoice  from  your  dealer  to 
confirm the date of purchase.

 

Before contact, have in hands the model of your autoclave, voltage, serial number, and 

the  date  of  manufacture,  found  in  the  identification  label  located  in  the  back  of  the 
equipment (Fig. 6, page. 8) and a description of the problem.

 

Always contact your local dealer

. If you have problems contacting your dealer, contact 

us through our website: www.cristofoli.com.

HOW TO PROCEED WHEN SERVICE IS NEEDED 

THE VACUUM PUMP STOPS AND DOES NOT SWITCH ON

•The motor is overheated and the thermal fuse was 
activated --------------------------------------------------------

•Wait until the motor  gets cold, if it doesn’t get back 

to  work,  see  “

How  To  Proceed  When  Service  Is 

Needed

” (Page 13).

•Verify voltage and electrical wire conditions;

POSIBLE CAUSES

SOLUTION

If the problem persists after the verification of all items, contact your local dealer.

C R I S T Ó F O L I

V A C U U M  P U M P S

I N S T R U C T I O N 

M A N U A L 

Содержание SuperGap Evolution 2

Страница 1: ... better serve its customers To fulfill all the requirements of the applicable standards promote the continuous improvement of its quality and environmental standards prevent pollution reduce its environmental impact and continuously train its staff achieving therefore a sustainable and profitable maximization of its value Rev 2 CRISTÓFOLI S MISSION CRISTÓFOLI QUALITY AND ENVIRONMENTAL POLICY Crist...

Страница 2: ...commendations and Warnings Installation Instructions Safety Devices Component Description How To Use the SuperGap Evolution Vacuum Pump How To Identify Your Autoclave Technical Data Preventive Maintenance Troubleshooting Quality Control How To Proceed When Service Is Needed Guidance For Final Disposal Of The Equipment Warranty Terms 03 04 04 04 05 09 09 09 10 10 11 12 13 13 14 15 ...

Страница 3: ...ection Terminal Date of Manufacture 3 Keep Dry Recyclable Keep out of sunlight This side up Fragile handle with care LOT SN Serial Number Lot number ISO 13485 13485 DE S G A E M S E T T Ã S I O S C R I S T Ó F O L I V A C U U M P U M P S I N S T R U C T I O N M A N U A L ...

Страница 4: ...ues from odontological treatments or surgeries INTENDED USE RECOMMENDATIONS AND WARNINGS Read all instructions of this manual before using your SuperGap Evolution The incorrect use may result in malfunction and or accidents For your safety when performing any kind of maintenance remember to unplug the power cord and use PPE Personal Protective Equipment Do not allow patients especially kids to get...

Страница 5: ... voltage device and it leaves the factory adjusted for 220 V For 127 V operation reposition the selector switch placed at the back of the equipment Fig 9 page 9 See How To Identify Your Vacuum Pump Fig 11 page 10 For installation use a grounded outlet 2 Pins Grounding 20 A plugging phase neutral or phase phase at the side pins and grounding at the middle pin Never plug the grounding on neutral Ele...

Страница 6: ...ressure must be around 3 to 40 wcm water column meters above 20 wcm it could be possible to hear an acute sound from the flow regulator Connect the hose with a 90 angle to the water inlet at the front of the vacuum pump Fig 8 page 9 and the other side to the water valve The water flow regulation is automatically done by an internal device Fig 8 page 9 SUCTION The pipe that connects the dental unit...

Страница 7: ...tall the noise reducer Fig 3 observing the arrow that indicates flow direction Figs 3 and 4 Attention The incorrect installation of the noise reducer backwards will cause damage to the vacuum pump Connect the R L adapter to the drain exit of the dental unit after it connect the hose to the adapter and fasten it with the clamp Note The vacuum pump and the cuspidor may be connected to the same drain...

Страница 8: ... most distant from the dental unit vacuum pump SuperGap 2 10 m max 32 mm Model Pipes length Pipes diameter Table 2 Fig 5 Fig 6 Strip Connector Residue Filter Voltage Selector Switch Identification Label Fig 7 45 C R I S T Ó F O L I V A C U U M P U M P S I N S T R U C T I O N M A N U A L ...

Страница 9: ...se it is necessary to wait for 2 minutes until the vacuum system is filled with water To turn on the vacuum pump just take the suction instrument out from it s support and to turn it off get the instrument into the support again so the vacuum pump will be automatically deactivated At the end of the workday clean the residue filter Fig 10 See Preventive Maintenance Page 11 HOW TO USE THE SUPERGAP E...

Страница 10: ...ification This equipment is manufactured by Cristófoli Biossegurança company whose the Quality Management System is certified by and in accordance with ISO 13485 2003 I Suitable for up to 4 dental units 14 6 kg 13 5 kg 23 2 cm x 23 5 cm x 35 cm 27 cm x 27 cm x 39 cm 127 220V AC single phase 60 Hz 0 16 l min 560 W 3 4 HP 0 56 h kW 300 liters min 3450 620 mm Hg 78 dB 70 0 a 75 70 106 kPa 5 ºC a 40 º...

Страница 11: ...and biodegradable neutral detergent after it clean with a cloth moistened with 70 alcohol and 1 peracetic acid Never use solvents or petroleum derivatives Verify the openings at the bottom of the motor if there s dirtiness accumulation on it perform cleaning YEARLY General revision and flow limiter regulation we recommend that this procedure be performed by an authorized technical assistance Unplu...

Страница 12: ...m tip remove de rivets and the cover locate the fuse and replace it by a new one Take out the the pushed plastic pins place the lid again and the plastic rivets Note To place the rivets insert the plastic pins at the center of the rivets about 2 mm put the rivets inside the holes and push the pins until they get alined with the rivets to lock it See Safety Devices Item 1 page 9 If the problem pers...

Страница 13: ...e date of manufacture found in the identification label located in the back of the equipment Fig 6 page 8 and a description of the problem Always contact your local dealer If you have problems contacting your dealer contact us through our website www cristofoli com HOW TO PROCEED WHEN SERVICE IS NEEDED THE VACUUM PUMP STOPS AND DOES NOT SWITCH ON The motor is overheated and the thermal fuse was ac...

Страница 14: ...EQUIPAMENTOS DE BIOSSEGURANÇA LTDA strongly recommends users of their products to seek the best destination when disposing equipment or components taking into account the materials recycling legislation effective in each country We advise you to take your equipment to specialized recycling companies that due to the continuous and fast paced development of new recycling technologies and materials r...

Страница 15: ...ng from natural causes such as floods lightning etc Sinister theft or robbery Damage caused by accidents such as dents drops short circuits fire etc Problems due to failure of the power supply and or building wiring Improper use installation of the equipment and or plugging it into an incorrect voltage outlet Removal and or tampering of the serial number shown in the identification label of the pr...

Страница 16: ......

Отзывы: