  Precautions regarding accidental earth leaks 

The  charger's  PE  terminal  must  be  earthed  and 
connected before any other terminal. 

The shore-power unit must be closed before it is turned 
on with the screw provided for this purpose. 

Accidental leakage current between phase and earth 

Standard NFC15-100 should be followed when installing. 

Use the services of an electrician or professional installer 
to make the necessary connections. 

Accidental  leakage  current  between  the  charge  circuit 
and the earth 

Accidental  current  leakage  at  the  earth  must  be 
detected by means of an independent protective device 
outside  the  shore-power  unit  (a  residual  current  device 
or an insulation detector). 

 

The  installer  should  decide  on  the  rating  and  nature  of 
the protection according to the risks. Special precautions 
should be taken on any installation prone to electrolyse 
phenomena.  Regulations  require  the  presence  of  a 
battery switch on the outputs of the + and the - poles. 
 

 

  Precautions regarding lightning 

In  areas  highly  exposed  to  lightning,  it  may  be 
advisable  to  install  a  lightning  arrestor  upstream  of 
the  shore-power  unit  to  safeguard  it  against 
irreversible damage. 

Содержание YPOWER UEYPO 12-16 2D

Страница 1: ...shore power units UEYPO 12 16 2D UEYPO 12 16 3D UEYPO 12 16 4D UEYPO 12 25 2D UEYPO 12 25 3D UEYPO 12 25 4D UEYPO 12 40 3D UEYPO 12 40 4D S A S CRISTEC 31 rue Marcel Paul Z I Kerdroniou Est 29000 QUI...

Страница 2: ...1 Manuel d utilisation en Fran ais 2 Operating Manual in English 22...

Страница 3: ...tallation 12 3 2 6 Dispositions vis vis des perturbations lectromagn tiques g n r es par l appareil 13 3 2 7 Principe de c blage 13 3 3 CONFIGURATION DES MICRO INTERRUPTEURS REGLAGES INDICATEURS 14 3...

Страница 4: ...l doit tre conserv avec soin et consult avant toute intervention car il contient toutes les informations relatives l utilisation de l appareil Ce document est la propri t de CRISTEC toutes les informa...

Страница 5: ...erre Se conformer la norme NFC15 100 pour les pr cautions d installation Courant de fuite accidentel entre circuit de charge et masse La d tection des courants de fuite accidentels la masse doit tre a...

Страница 6: ...dans ce manuel Il est imp ratif de conserver une zone de 150mm autour de l appareil L installateur prendra les dispositions n cessaires pour que la temp rature d air l entr e soit inf rieure 40 C dans...

Страница 7: ...mmables L unit d nergie ne doit pas tre utilis proximit de mat riels liquides ou gaz inflammables Les batteries sont susceptibles d mettre des gaz explosifs pour l installation des batteries prendre e...

Страница 8: ...ais de port et d emballage les frais de d montage remontage et tests ainsi que tous les autres frais non cit s Notre garantie ne peut en aucun cas donner lieu une indemnit CRISTEC ne peut tre tenu pou...

Страница 9: ...chargeur de l unit d nergie est enti rement automatique apr s s lection pr alable du type de batterie et du type de charge Il peut rester raccord de fa on permanente aux batteries sauf stipulation co...

Страница 10: ...it par 4 vis M5 t te ronde Entraxe de fixation voir plan correspondant annexes 3 et 4 3 1 ENCOMBREMENT DU CHARGEUR Unit s UEYPO 12 16 et UEYPO 12 25 voir annexe 3 Unit s UEYPO 12 40 Voir annexe 4 3 2...

Страница 11: ...ur des tensions 185VAC 1 Consulter CRISTEC pour toute utilisation en 115VCA 60Hz Groupes lectrog nes Les unit s d nergie CRISTEC sont con us pour fonctionner sur groupe lectrog ne Attention Dans certa...

Страница 12: ...au nombre de 2 3 ou 4 selon mod le doivent tre de section 2 5mm Le type de c ble H07 VK MX etc devra tre d fini par l installateur en fonction du type d application et des normes applicables Le couran...

Страница 13: ...YPO 12 40 16mm Le type de c ble H07 VK MX etc devra tre d fini par l installateur en fonction du type d application et des normes applicables Les sorties batteries et ou utilisation se font imp rative...

Страница 14: ...er les c bles au plus pr s des masses les c bles volants ou les boucles sont viter plaquer les c bles contre les masses S parer les c bles d alimentation et d utilisation S parer les c bles de puissan...

Страница 15: ...s batteries Cette fonction est temporis e dans le temps voir tableau ci apr s et est inhib e automatiquement si la batterie est charg e arr t du BOOST pour Un courant batterie 20 du courant nominal du...

Страница 16: ...13 4V 0H 0H 1 1 1 0 Alimentation stabilis e 12 0V 12 0V 0H 0H 0 0 0 1 Bat type ouverte SPE1 13 2V 14 8V 2H 4H 1 0 0 1 Lithium Fer Phosphate LiFePO 4 avec BMS 13 8V 14 4V 6H 10H 0 1 1 1 R serv 1 1 1 1...

Страница 17: ...tension entr e AC et sortie DC et ventuellement ajuster la tension de sortie vide via le potentiom tre R432 utiliser l outil ad quat pour tourner la vis du potentiom tre en fonction du type de batter...

Страница 18: ...c dent paragraphe 3 3 2 Phase BOOST D marre automatiquement la mise sous tension du chargeur si la batterie est d charg e Le courant est alors maximum Phase ABSORPTION Commence d s que la tension a at...

Страница 19: ...er IU Il g n re une tension constante et fournit le courant n cessaire la ou les batteries Le temps de recharge d pend de l tat de la batterie et est plus long que dans la configuration BOOST en posit...

Страница 20: ...les d p ts de poussi re pouvant alt rer l vacuation de la chaleur V rifier l tat de charge des batteries tous les 3 mois Une v rification annuelle du serrage des crous et vis est n cessaire pour garan...

Страница 21: ...fixation 375 x 158 mm 375 x 158 mm 422 x 180 mm Vis de fixation murale 4 vis M5 t te ronde Indice de protection IP20 Normes Marquage CE CEM NF EN61000 6 1 NF EN61000 6 2 Marquage CE s curit NF EN6095...

Страница 22: ...u IUoU Boost Absorption Floating et Refresh configuration usine Type de batteries Plomb tanche par d faut Autres s lections par commutateurs internes Gel AGM Plomb Calcium Alimentation stabilis e etc...

Страница 23: ...e earth to the installation 32 3 2 6 Precautions regarding electromagnetic disturbance generated by the appliance 33 3 2 7 Cabling principle 33 3 3 Switches setting adjustment indicators 34 3 3 1 Desc...

Страница 24: ...ulted before attempting any repairs because it contains all the information required to use the appliance This document is the property of CRISTEC all the information it contains applies to the accomp...

Страница 25: ...e circuit and the earth Accidental current leakage at the earth must be detected by means of an independent protective device outside the shore power unit a residual current device or an insulation de...

Страница 26: ...either side of the shore power unit It s strictly forbidden to put any device on or against the shore power unit The shore power unit must not be installed near a heat source it should be installed in...

Страница 27: ...er s instructions carefully when installing them Nearby the batteries ventilate the area do not smoke do not use any open flame Use fuses as defined in this manual Other precautions Never attempt to d...

Страница 28: ...d packaging disassembly reassembly and testing costs as well as all other costs not mentioned Our warranty on no account provides for any form of compensation CRISTEC shall not be held liable for dama...

Страница 29: ...been selected operation of the shore power unit is entirely automatic unless otherwise specified by the supplier or the manufacturer of the batteries It can remain connected to the batteries and does...

Страница 30: ...nce see corresponding drawing in appendix 3 et 4 3 1 CHARGER OVERALL DIMENSIONS Shore power unit UEYPO 12 16 and UEYPO 12 25 refer to appendix 3 Shore power unit UEYPO 12 40 refer to appendix 4 3 2 WI...

Страница 31: ...s below 185VAC 1 Consult CRISTEC for 115VCA 60Hz applications Generators The CRISTEC shore power units are designed to operate from a generator Be careful In some cases the generators can produce high...

Страница 32: ...st be 2 5mm The installer should define the type of cable H07 VK MX according to the type of application and the applicable standards The current in the cable must not exceed 10A Always use cable mark...

Страница 33: ...16mm The installer should choose the type of cable H07 VK MX etc according to the type of application and the applicable standards The DC outputs must use a PHOENIX CONTACT connector type If you do n...

Страница 34: ...ssible to conductive parts loose cables or loops should be avoided cables should be placed against the hull or walls Keep power cables separate from battery cables Keep power cables separate from cont...

Страница 35: ...of the batteries This function is timed controlled see table here after and is automatically switched off when the battery is fully charged BOOST stops when batteries current 20 of charger rated curre...

Страница 36: ...d bat 13 4V 13 4V 0H 0H 1 1 1 0 Stabilized DC power supply 12 0V 12 0V 0H 0H 0 0 0 1 SPE1 open type bat 13 2V 14 8V 2H 4H 1 0 0 1 Lithium Iron Phosphate LiFePO4 with BMS 13 8V 14 4V 6H 10H 0 1 1 1 Boo...

Страница 37: ...ding input and output voltage and possibly adjust the output voltage with no load using potentiometer R432 use the appropriate tool to turn the screw of the potentiometer depending on the type of batt...

Страница 38: ...2 BOOST phase Starts up automatically when the charger is turned on if the battery is flat The current is then at maximum output ABSORPTION phase Begins when the voltage has reached the maximum BOOST...

Страница 39: ...With this setting the YPOWER shore power unit produces a single stage UI type charge curve It generates a constant voltage supplying the current required by the battery ies Recharging time depends on...

Страница 40: ...t deposits may adversely affect heat dissipation Check the state of battery charge every 3 months Nuts and screws should be tightened annually to ensure efficient operation of the appliance particular...

Страница 41: ...l 4 M5 round screws Protection factor IP20 Board protection Protected with water repellent varnish marine environment Standards CE EMC marking NF EN61000 6 1 NF EN61000 6 2 CE safety marking NF EN6095...

Страница 42: ...loating and Refresh factory setting Battery type Lead sealed as factory setting Other choices through internal setting gel AGM Calcium Lead Stabilized power supply etc Regulated and filtered output vo...

Страница 43: ...38 Annexes Appendix...

Страница 44: ...ervice 2 ou auxiliaire 2 Service battery 2 or auxiliary 2 R glages Setting Einstellungen Ajustes Regolazioni A B C D Configuration des courbes de charges Load curve setting E Configuration du BOOST BO...

Страница 45: ...Service battery 2 or auxiliary 2 R glages Setting A B C D Configuration des courbes de charges Load curve setting E Configuration du BOOST BOOST setting F Configuration du REFRESH REFRESH setting R43...

Страница 46: ...egr d IP Place the charger vertically connection downwards Failure to respect this position may cause a decrease in available power and a loss of IP level Zone de d gagement de 150mm autour du chargeu...

Страница 47: ...d IP Place the charger vertically connection downwards Failure to respect this position may cause a decrease in available power and a loss of IP level Zone de d gagement de 150mm autour du chargeur p...

Страница 48: ...terie Moteur Mounting 1 Engine Battery Montage 1 Batterie Moteur 1 Batterie Service Mounting 1 Engine Battery 1 Auxiliary Battery Montage 1 Batterie Moteur 2 Batteries Service Mounting 1 Engine Batter...

Страница 49: ...44 Montage 2 Batteries Service Mounting 2 Auxiliary Batteries Montage 3 Batteries Service Mounting 3 Auxiliary Batteries...

Страница 50: ......

Отзывы: