background image

 

FS-40 

Alarm / Remote Start Combo System 

 

INSTALLATION HANDBOOK: 

 

INTRODUCTION 

 

Congratulations  on  your  choice  of  a  Crimestopper  combination  alarm  &  remote  engine  starter  with  Data  Port 
Technology.   

 

This  installation  book  is  designed  for  the  installer  or  individual  with  an  existing  understanding  of 
automotive electrical systems, along with the ability to test and connect wires for proper operation.  To ease 
installation,  we  suggest  that  you  READ  THIS  MANUAL  before  beginning  your  installation.    This  book  is 
provided as a GENERAL GUIDELINE and the information contained herein may differ from your vehicle. 

 

DISCLAIMER: 
Crimestopper Security Products, Inc. and its vendors shall not be liable for any accident resulting from the 
use  of  this  product.    This  system  is  designed  to  be  professionally  installed  into  a  vehicle  in  which  all 
systems and associated components are in perfect working condition. 

 
 

TECHNICAL SUPPORT (800)-998-6880 
Monday - Friday 8:00am - 4:30pm Pacific Time 

 

Website: www.crimestopper.com 

 

CRIMESTOPPER SECURITY PRODUCTS, INC. 
1770 S. TAPO STREET 
SIMI VALLEY, CA. 93063 

 

REV.  11.2008 

This  device  complies  with  FCC  Rules  part  15.  Operation  is 
subject to the following two conditions: 1) This device may not 
cause  interference,  and  (2)  this  device  must  accept  any 
interference  that  may  be  received,  including  interference  that 
may  cause  undesired  operation.    The  manufacturer  is  not 
responsible  for  any  radio  or  TV  interference  caused  by 
unauthorized 

modification 

to 

this 

equipment. 

Such 

modification  could  void  the  user's  authority  to  operate  the 
equipment.

 

Содержание Fortress FS-40

Страница 1: ...be liable for any accident resulting from the use of this product This system is designed to be professionally installed into a vehicle in which all systems and associated components are in perfect wo...

Страница 2: ...GINNING check all vehicle manufacturer cautions and warnings regarding electrical service AIR BAGS ABS BRAKES ENGINE BODY COMPUTER AND BATTERY PLAN OUT YOUR INSTALLATION You should pre determine the l...

Страница 3: ...oor performance COMPONENT MOUNTING CONTROL MODULE The alarm control module should be mounted in a concealed location DO NOT mount the control unit in the engine compartment Fasten the module to a brac...

Страница 4: ...wn without the need for an external Turbo Timer See operator s manual for more information Brown Siren Output Connect brown wire to siren red wire Connect black wire of siren to chassis ground body me...

Страница 5: ...hicle Connect to 12V for Positive circuits or Ground for Negative circuits Relay not included AUX OUTPUT OR OR Blue Black 500mA IGNITION OUT or REMOTE AUX Output 2 Programmable Option 17 This wire fun...

Страница 6: ...ket for the starter disable Connect the blue wire of the relay socket to the Ignition switched wire on the vehicle Cut the vehicle starter wire and connect each half to an Orange wire on the relay soc...

Страница 7: ...cle parking light circuit at the back of light switch or if this is not possible connect directly to one of the parking lights at the front of the vehicle If your vehicle has a multiplex lighting syst...

Страница 8: ...nk pin switches that read ground when open If no existing switches are available install new pin switches if desired Note DO NOT mount new pin switches in water pathways Pink 12V Diesel Glow Plug Inpu...

Страница 9: ...ut the keys or if the Ignition key is not turned on all the way WIRING 2 PIN LED 2 PIN Program Valet Button 26 gauge wires Mount LED in a visible location on the Dash or Console Connect the small 2 pi...

Страница 10: ...ter clockwise will decrease sensitivity Adjust Pre Warning level with small Black dial GREEN LED RED LED PRE WARN TRIGGER GROUND 12 VOLTS WHITE BLUE BLACK RED Trigger Pre Warn Adjustments SHOCK SENSOR...

Страница 11: ...on vehicles with retained accessory power BLUE ORANGE STARTER 3 This wire provides a ground output for vehicle that requires a third starter wire to remote start BLUE ORANGE CONNECT TO IGN 85 86 30 8...

Страница 12: ...vehicle doors Reverse Polarity Many Ford Lincoln Mercury Dodge Chrysler Plymouth and early 90 s GM Trucks Reverse Polarity systems use no relays but instead the door lock unlock motors are controlled...

Страница 13: ...ED 12V 12V BLUE BLUE 86 85 86 85 86 85 86 85 87 87 87 87 30 87A 30 87A 30 87A 30 87A L CUT UL CUT MASTER SWITCH NEGATIVE TRIGGER DOORLOCK WIRING POSITIVE TRIGGER DOORLOCK WIRING GREEN GREEN FUSED RED...

Страница 14: ...EEN RED BLUE DRIVER S DOOR MOTOR 86 85 L L 87 UL UL 87A 30 FACTORY LOCK RELAYS 12V FUSED UNLOCK WIRE CUT WIRING FOR REVERSE POLARITY DOOR LOCKS BLUE WHITE GREEN FUSED RED 12V BLUE MASTER 86 85 86 85 S...

Страница 15: ...int Raising or lowering this 93 point should increase or decrease your cranking time respectively You can adjust the range from 79 to 100 in one percent increments Factory default setting starting poi...

Страница 16: ...ing lights to flash NOTE On vehicles equipped with daytime running lights it may be difficult to see any flashing parking lights In this case your only notification will be the slight ticking sound co...

Страница 17: ...he engine to get a feel of how long the cranking time is Once the Timed Crank mode is turned on the default cranking time is set to a Default of 0 50 seconds We recommend beginning with this setting T...

Страница 18: ...ow Plug input wire 2 Once this option has changed the system will wait for the selected time before cranking the engine PROGRAMMABLE OPTIONS You can program multiple options in one session if you star...

Страница 19: ...eries or SL Series OFA Series SL Series 8 Remote Start Auxiliary Output Button Press Selection Double Button Press Second Press Press and Hold 9 Siren Chirps on Remote Start OFF ON 10 Disarm on Trunk...

Страница 20: ...Steady Momentary Momentary Timed Latch On Off 29 Aux 4 Time 1 to 255 sec 1 Second 1 Second Default 12 Sec 30 Turbo Timer Mode 1 to 5 Minutes Brake Pedal Set Mode Always Set Mode Idle Down Mode 31 Res...

Страница 21: ...llumination near your vehicle when approaching at night for safety 7 Data Port Protocol This option controls the Data Port Protocol for OFA Series modules or SL Series modules The default is set for S...

Страница 22: ...tion controls the function of the Blue Black wire as either a Ground with Remote Start or a 2nd Aux Channel 18 SIREN CHIRPS WITH ARM DISARM With this feature siren chirps with Arm Disarm can be progra...

Страница 23: ...default 93 setting works for most vehicles See page 15 for additional Ultra Smart Tachless mode information 25 FACTORY HORN CHIRPS PULSES This option controls the system s horn honk output There are...

Страница 24: ...emote The lights flash 2 times and all values will be reset to factory original settings Default values are marked with asterisks in the chart on pages 20 and 21 PROGRAMMABLE OPTION RESET This system...

Страница 25: ...tter You should get 2 light flashes indication the unit is waiting for a 2nd code then press the same combination of buttons on a second remote the unit will flash 3 times indicating its waiting for t...

Страница 26: ...the system is re armed REMOTE START DIAGNOSTICS If the system flashes the parking lights one to three times and doesn t attempt remote it means the following 1 Parking Light Flash Problem with Brake...

Страница 27: ...ght WHITE wire and the Glow Plug PINK wire See the diagrams below for Jumper Pin configurations Parking Lights Start 2 IGN 2 ACC 2 Control Module High Current Plug Antenna Plug Data Port Plug Program...

Страница 28: ...28 ANTENNA DIAGRAM Antenna should be located at top of widow at least one inch away from metal surface WINDSHIELD ANTENNA LOCATIONS...

Страница 29: ...RT IGN ACC ACC Control START 2 IGN 2 ACC 2 Fuel A C Heater Pump Coil Jumper Select Default IGN 2 STARTER 12 Volt Battery Fuse Fuse Gray Pink Pink White Brown Red Red IGNITION SWITCH Diagram not to sca...

Страница 30: ...ry Car Horn JUMPER SELECT Pink White Pink Grey Brown Red Red Accessory 1 Starter 1 Ignition 1 Fuse Fuse 12 Volts Brown Brown White Black White Green Red Blue White Blue Black 86 85 87 30 87A Dome Ligh...

Страница 31: ...t for SL series Protocol Please refer to Databus module manual for detail instructions The Data Port Protocol must be programmed for the correct module See Option 7 on page 19 Vehicle ign with Anti th...

Страница 32: ...www crimestopper com Phone 800 998 6880 FAX 805 581 9500 2008Crimestopper Security Products ONLINE TECHNICAL SUPPORT www crimestopper com...

Отзывы: