Congratulations on your choice of a Crimestopper EZEE Start remote engine starter!  This installation Handbook covers 
the following models: EZ-90 Remote Start & Keyless Entry System, EZ-91 Upgrade/Expansion module (No remotes or 
antenna), and the 2-Way Systems: EZ-777TW1, EZ-777TW2 & EZ-777FM. 

 

DISCLAIMER: 
This installation book is designed for the installer or individual with an existing understanding of automotive electrical 
systems, along with the ability to test and connect wires for proper operation.  To ease installation, we suggest that you 
READ THIS MANUAL before beginning your installation.  This book is provided as a GENERAL GUIDELINE and the 
information contained herein may differ from your vehicle.  Crimestopper Security Products, Inc. and its’ vendors shall 
not be liable for any accident resulting from the use of this product.  This system is designed to be professionally 
installed into a vehicle in which all systems and associated components are in perfect working condition. 

 
 

TECHNICAL SUPPORT: (800) 998-6880 

This device complies with FCC Rules part 15.  Operation is subject to 
the following two conditions:  (1) This device may not cause harmful 
interference, and (2) This device must accept any interference that 
may be received, including interference that may cause undesired 
operation.  The manufacturer is not responsible for any radio or TV 
interference caused by unauthorized modifications to this equipment. 

Such modification could void the user’s authority to use the 

equipment.

Monday - Friday 8:00am - 4:30pm Pacific Std. Time 
Web Site: www.crimestopper.com 
E-mail: [email protected] 

 

CRIMESTOPPER SECURITY PRODUCTS, INC. 
1770 S. TAPO STREET, SIMI VALLEY, CA. 93063 

 

REV A  08.2004 

 
 
 
 
 

Содержание Ezee Start EZ-777 FM

Страница 1: ...r vehicle Crimestopper Security Products Inc and its vendors shall not be liable for any accident resulting from the use of this product This system is designed to be professionally installed into a v...

Страница 2: ...e locations for all components to be placed These components include the module itself valet program button possible relays and antenna receiver EZ 90 777TW1 TW2 FM only EZ 91 model does not include i...

Страница 3: ...re to terminal 85 connect relay terminals 86 and 87 to 12V constant power Connect terminal 30 to the 12V positive Horn activation wire PIN 10 BLACK MAIN SYSTEM GROUND Connect to chassis metal of the v...

Страница 4: ...DULE 12V CONSTANT OR TRANSPONDER Diode isolate if using both PIN 9 YELLOW BLACK FOR ANTI GRIND STARTER DISABLE OUTPUT Relay not included TO IGN 2 MOTOR ACC START CUT BROWN YELLOW BLACK 86 85 MAKE CERT...

Страница 5: ...or use as a dome light illumination output Note when using the Brown wire as a Trunk Pop you may also need or want to program option 14 so the system also provides an Unlock signal when the trunk pop...

Страница 6: ...Remote Start or Stop when 3 successive Negative pulses are sent to the Green input wire Connect the Green input wire to the Negative lock signal wire of the factory system If your Factory OEM system d...

Страница 7: ...ORANGE BLACK OEM DISARM OUTPUT This wire provides a Ground pulse to disarm the vehicles Factory anti theft system prior to a Remote Start Connect this wire to the vehicles anti theft disarm wire This...

Страница 8: ...more than just one IGN ACC or STARTER wire in order to start and run successfully If this is the case for your particular vehicle then use the jumper pin located under the access panel on the top of t...

Страница 9: ...C 2 TOP WHITE START 2 FUSE PARKING LIGHTS IF NECESSARY 7 PIN High Current Connector IGN SWITCH VEHICLE 10A or 500mA NOTE Heavy duty High Current Ignition circuits greater than 30 AMPS Industrial vehic...

Страница 10: ...cle doors Reverse Polarity Many Ford Lincoln Mercury Dodge Chrysler Plymouth and early 90 s GM Trucks Reverse Polarity systems use no relays but instead the door lock unlock motors are controlled dire...

Страница 11: ...LUE BLUE 86 85 86 85 87 87 30 87A 30 87A FACTORY FACTORY L L POWER POWER LOCKING LOCKING UL UL RELAYS RELAYS AFTERMARKET MOTOR DOOR LOCK WIRING REVERSE POLARITY DOOR LOCK WIRING GREEN GREEN FUSED FUSE...

Страница 12: ...decrease your cranking time respectively The adjustment range is from 80 to 100 in one percent increments Follow steps below to adjust the reference level 1 Open hood or ground Gray wire if no hood p...

Страница 13: ...m may flash the lights erratically Erratic light flashing indicates that the system is sensing and tach pulse but it is not programmed into memory To correct this issue follow the tach programming ste...

Страница 14: ...TACH PROGRAMMING 1 Open hood or ground Gray hood pin wire if no hood pin is installed 2 Red White wire should be connected to a valid Tach source 3 Start engine with key 4 Press program button 5 time...

Страница 15: ...e key start the engine a few times to get a feel of how long the cranking time is Once the Timed Crank mode is turned on the default cranking time is set to a default of 0 50 seconds We recommend begi...

Страница 16: ...30 seconds SEE OPTION PROGRAMMING CHART on Pages 17 18 HOW TO USE THIS FEATURE 1 See the Option Programming section on Pages 17 18 and change Option 19 from Monitor Glow Plug Light to one of the delay...

Страница 17: ...s Tap the brake once lights flash 1X Tap the brake pedal again Lights flash 2X tap 3 or 4 times for options that have 3 or 4 values 6 When finished turn Ignition OFF close hood or un ground Gray wire...

Страница 18: ...17 OEM Disarm Unlock Pulse 0 75 sec Normal or 0 5 Shorter Short Normal 18 Starter Cranking Time Only when option 15 is set for Timed Crank Button 1 0 75 Sec Button 2 0 5 Sec Button 3 1 0 Sec Button 4...

Страница 19: ...4 Double Unlock Pulse The unit will send 2 unlock pulses when the 2 Unlock button is pressed This feature may be required for interfacing this alarm with an existing Factory Keyless Entry or Alarm sy...

Страница 20: ...Negative IGN output that turns ON and stays on for the duration of the remote start Use this wire to turn on Anti theft bypass adapters for GM or Transponder systems When changed to an Anti Grind this...

Страница 21: ...gnal Just select a delay time and do not connect the Pink Glow Plug wire Selections 10 20 30 seconds or Monitor Pink Wire Default 20 Remote Start Run Time This option controls the engine run time for...

Страница 22: ...not starting vehicle 3 Press Program Valet button 4 times After a few seconds the unit will flash the parking lights exactly 4 times 4 EZ 90 Press Button 1 Lock of the transmitter to be learned EZ 77...

Страница 23: ...system remote CANNOT control an EZ 777TW1 TW2 FM and vice versa See diagram below on how to switch your remote s to vehicle 2 operation To set up the 2 Vehicle operation you must first program your re...

Страница 24: ...y Passlock and RF Transponder systems Ford P A T S Many late 1990 s through 2005 vehicles include some type of Anti Theft system which may require a bypass module The vehicle may have more than one Ig...

Страница 25: ...INK glow plug input wire See the diagrams below for Jumper Pin configurations JUMPER PLUG SIDE VIEW JUMPER PINS JP1 JUMPERS IGN 2 DEFAULT ACC 2 NEGATIVE PARKING LIGHT 500 mA 12V 10A PARKING LIGHT DEFA...

Страница 26: ...ANTENNA DIAGRAM WINDSHIELD ANTENNA LOCATIONS Blue Plug Black Plug EZ 90 EZ 777TW1 EZ 777TW2 EZ 777FM Color of plug and receptacle must match 26...

Страница 27: ...XTERNAL RELAYS FOR HIGH CURRENT YELLOW WHITE OEM REARM START ACTIVATION GREEN HORN CHIRP HONK OEM DISARM GREATER THAN 30A IGNITION CIRCUITS ACC GROUND AUX TRUNK POP or DOME LIGHT FUSE FUSE 30A TACH 30...

Страница 28: ...ONLINE TECHNICAL SUPPORT www crimestopper com techweb03 html www crimestopper com email crimestopper com Phone 800 998 6880 FAX 805 581 9500 2004 Crimestopper Security Products...