background image

Removal and Replacement of ProStock Drawers 

 

Installation of Locker Drawer

 

 

8.  Unplug diodes from wiring harness and then plug the connectors that were previously connected to 

the each end of the diodes together 

(see Figures 11 and 12)

.  

 

Figure 11, Connectors Showing One (1) Diode Removed 

 

Figure 12, Connectors Connected without Diodes 

9.  Replace ProStock side cover. 

Connectors Connected 

With Diodes Removed 

Connectors with 

Diode Removed 

Diode 

 

 

13 of 13 

Содержание ProStock

Страница 1: ...Removal and Replacement of a ProStock Carousel Drawer with a Carousel or Locker Drawer Revision 1 March 7 2014...

Страница 2: ...ent of a ProStock Carousel Drawer with a Carousel or Locker Drawer Revision 1 Copyright Cribmaster 2014 CribMaster 1955 West Oak Circle Marietta Georgia 30062 770 419 1399 888 419 1399 Technical Suppo...

Страница 3: ...Removal and Replacement of ProStock Drawers Table of Revisions Date Revisions Revision Number March 13 2014 Initial Release of Document 1 3 of 13...

Страница 4: ...de ProStock Cabinet 6 Figure 2 Carousel Removal from Drawer 7 Figure 3 Screw Locations on Drawer Guides 8 Figure 4 Removal of Carousel Drawer 8 Figure 5 Installation of Carousel Drawer 9 Figure 6 Caro...

Страница 5: ...tem in a ProStock Locker Setting Up the ProStock 1 3 Document Conventions The following conventions for notes cautions and warnings will be used within this documentation Note This will contain genera...

Страница 6: ...to the ProStock machine 2 Unlock the drawers by unlocking the two barrel locks located at the top of the ProStock machine 3 Slide out the drawer to be removed 4 Reaching behind the left side of the d...

Страница 7: ...Figure 2 Carousel Removal from Drawer 6 Using a Philips head screwdriver remove the four screws two on the left side and two on the right side attaching the drawer to the drawer guides see Figure 3 L...

Страница 8: ...ully lift the front part of the drawer up at an angle removing tabs on the sides of the drawer from the slots on the drawer guides see Figure 4 Figure 4 Removal of Carousel Drawer Drawer Tabs 4PL 2 Ri...

Страница 9: ...r line up the rear tabs on the drawer with the rear slots on the drawer guides As the rear tabs are slid into place lower the front of the drawer ensuring that the front drawer tabs are inserted into...

Страница 10: ...using the locking hub nut see Figure 2 Note Do not over tighten locking hub nut Hand tighten only 7 Plug in the drawer s power data cable to the appropriate plug located inside the cabinet of the ProS...

Страница 11: ...the ProStock Machine 2 Remove Carousel Drawer or Locker Drawer from the ProStock machine following the steps in Section 2 Removal of Carousel Drawer on page 6 3 With one person on each side of the dr...

Страница 12: ...wn as shown in Figure 7 Failure to do so can risk injury when reaching for items inside of an installed locker 5 Plug in the drawer s power data cable to the appropriate plug located inside the cabine...

Страница 13: ...ug the connectors that were previously connected to the each end of the diodes together see Figures 11 and 12 Figure 11 Connectors Showing One 1 Diode Removed Figure 12 Connectors Connected without Di...

Отзывы: