CREVIS FnIO S Series NA-9286 Скачать руководство пользователя страница 8

5. Name of each Part 

6. Setting 

* Specifications and designs may be changed without advance Notice. 

 Caution 

-

If you use a hub. 

     Install the hub in between the master and the first NA-9286. 
     After connecting the cable to the hub and NA-9286 (In Port), other nodes connected as shown  
     in the figure above. 
 
-    Uses are recommended to use the communication cable for a strong tolerance from the noise. 

Status  LED Window(refer to the 
description below) 

RJ-45 Connector (IN) 

Latch for DIN Rail 

*1 

Removable Terminal Block 

RJ-45 Connector (OUT) 

Serial Communication Connector  
( RS-232) 

CREVIS Co., Ltd 

29-4, Gigok-ro, Giheung-gu, Yongin-si, Gyeonggi-do, Korea 446-930 

TEL : +82-31-899-4599  FAX : +82-31-899-4509 

Homepage : www.crevis.co.kr 
 

Содержание FnIO S Series NA-9286

Страница 1: ...10G m 100m EMC ESD EN 61000 6 2 2005 EN 61000 6 4 A11 2011 Kbps 10 100Mbps FnIO S series 63 RJ 45 2 Class 2 24VDC 24VDC 11VDC 28 8VDC 100mA typical 24Vdc 10A Byte Input 252bytes Output 252bytes Fn BU...

Страница 2: ...2 System Field 1 System Field 1 System System EtherCAT 2 Field I O 2 System Power Supply Field Power Supply 3 Tape 4 5 System I O 3 3 1 Din Rail 3 2 Din Rail Din rail Din Rail 2 1 System...

Страница 3: ...lickering EEPROM CPU RUN LED INIT Blinking PREOP Single Flashing SAFEOP Flickering BOOT OP ERR LED Blinking Single Flashing Double Flashing Flickering PDI I O LED Flickering Fn BUS Fn BUS Fn BUS Flick...

Страница 4: ...5 6 Master NA 9286 IN port NA 3 5 5 LED IN DIN Rail 1 2 4 OUT RS 232 29 4 TEL 031 899 4599 FAX 031 899 4509 Homepage www crevis co kr...

Страница 5: ...s explosion risk in hazardous locations Be sure that the area is non hazardous or remove system power appropriately before assembling or wiring the modules Do not touch any terminal blocks or IO modul...

Страница 6: ...k for complicated mount Pull up the module to remove from the din rail 2 2 Notice for Wiring of communication and Field power 1 The communication power and Field power respectively are supplied to eac...

Страница 7: ...nvalid Configuration Invalid Configuration Single Flashing Red Unsolicited State Change Local Error Double Flashing Red Application Watchdog Timeout Process Data Watchdog Timeout EtherCAT Watchdog Tim...

Страница 8: ...connected as shown in the figure above Uses are recommended to use the communication cable for a strong tolerance from the noise 3 5 5 Status LED Window refer to the description below RJ 45 Connector...

Отзывы: