Crestron ST-LT Скачать руководство пользователя страница 6

 CRESTRON  

ST-LT Physical Views 

 

ST-LT Ports 

A number of ports are provided on the back of the ST-LT. Each has a silk-screened 
label. Refer to illustration and descriptions below.  

ST-LT Ports 

 

12 VDC .5 A 

This DC power socket connector is used to supply external power via the supplied 
500 mA power pack (1000 mA power pack for the STI-LT). If the ST-LT is part of 
the CRESNET II System, use of the supplied power pack is optional.  

2  

  Lutron Interface 

Operations Guide - Doc. 5694 

Содержание ST-LT

Страница 1: ......

Страница 2: ......

Страница 3: ...AFIK Eye Use 7 Preparation for Use 9 Programming 10 Problem Solving 16 Troubleshooting 16 Further Inquiries 16 Syntax 16 Return and Warranty Policies 17 Merchandise Returns Repair Service 17 CRESTRON...

Страница 4: ......

Страница 5: ...S to interface with a Lutron GRAFIK Eye Lighting System Future ST LT production models shall permit an interface with the Lutron Homeworks System If the ST LT is part of the CRESNET II System use of t...

Страница 6: ...er to illustration and descriptions below ST LT Ports 12 VDC 5 A This DC power socket connector is used to supply external power via the supplied 500 mA power pack 1000 mA power pack for the STI LT If...

Страница 7: ...s chained for additional network devices that are connected RS 232 This 9 pin DB9 connector is a Lutron compatible RS 232 interface for connections to a PC running Lutron configuration and control sof...

Страница 8: ...SIMPL program currently loaded has a network device defined at the same ID as the ST LT CRESTRON SND This LED flashes when the ST LT sends a command to the Lutron Mux Link Network CRESTRON RCV This LE...

Страница 9: ...RESNET II requires a unique identity code NET ID These codes are recognized by a two digit hexadecimal number from 03 to FE The NET ID of each unit must match an ID CODE specified in the NET ID statem...

Страница 10: ...ter and OPS version 3 16 11 or higher required Attach ST LT to CRESNET II system verify that the workshop is open and running and complete the following steps to change the NET ID 1 Disconnect all net...

Страница 11: ...itch Settings for GRAFIK Eye Use An eight position dip switch is mounted to the ST LT PC board The switch positions switches 6 and 7 ON are factory set for typical use of the ST LT within a CRESNET II...

Страница 12: ...ription for GRAFIK Eye Use SWITCH FUNCTION DESCRIPTION 1 Zone Lock Retain Zone locked units will remain in zone lock after a power outage 2 Scene Lock Retain Scene locked units will remain in scene lo...

Страница 13: ...5682 when making connections to the port labeled NET SmarTouch STS Hookup Connections for ST LT NOTE USE 2 FOOT SUPPLIED CABLE CA15717 OR EQUIVALENT EXTENDED LENGTH TO CONNECT ST LT TO SMARTOUCH STS D...

Страница 14: ...ch System from the File menu to open a specific SmarTouch system The software displays the SmarTouch Pro Editor dialog box formally known as SmarTouch System Manager 2 Double click on the next availab...

Страница 15: ...etails Lighting Page Sample HINT An alternate method would be to address the MAIN UNIT when the button that opens the lighting page is depressed Buttons on the lighting page can then be assigned indiv...

Страница 16: ...dresses MAIN UNIT 2 Click on Insert Command ZONE 1 UP from the Function area and OK Once the macro is complete select OK to close the Macro Edit dialog box 12 Next the function must be assigned to a s...

Страница 17: ...be ramped up and down The MV symbols are used to detect the release of the UP and DOWN buttons which results in the transmission of the appropriate zone up down stop commands Workshop The CRESNET II W...

Страница 18: ...and stop bits are not used and may be set to any value If Port B is defined to be 9600 N81 a RS 232 link to the Grafik Eye unit through the RS 232 port on the back of the ST LT is permitted The RS 23...

Страница 19: ...ne Lower Stop E NONE E stop ramping down all zones on all units Zone Raise B main unit zones B5 stop ramping up all zones on unit 5 B3124 ramp up zones 1 2 4 on unit 3 Zone Raise Stop C NONE C stop ra...

Страница 20: ...rk power supply is securely attached to the network Further Inquiries If after reviewing this Operations Guide for the ST LT you can not locate specific information please take advantage of CRESTRON s...

Страница 21: ...s warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any...

Страница 22: ...statement in the following form is reported CR LF ERROR 6 0 OK CR LF The first number indicates the type of error and the second number indicates the number of commands executed before the error When...

Страница 23: ...ch 2 releases it Examples SL CR Release all GRAFIK Eye Main Units from scene lock SL2 CR Scene lock GRAFIK Eye Main Unit 2 and release all others SL 3 CR Release GRAFIK Eye Main Unit 3 from scene lock...

Страница 24: ...ce mode SQ 68 CR Sequence GRAFIK Eye Main Units 6 and 8 in addition to the units already selected SQ 3 CR Take GRAFIK Eye Main Unit 3 out of sequence mode while not affecting the status of other GRAFI...

Страница 25: ...D command with no zones and all GRAFIK Eye Main Units Example E CR Stop all zones on all GRAFIK Eye Main Units that are ramping down B Zone Raise This command causes the zone s listed on the given GR...

Страница 26: ...to Tuesday RT Report Time This command reports the current time and date of the internal timeclock If this command is entered on a GRX AV RS232 unit an error condition is issued Example RT CR Report...

Страница 27: ...to report the time that the sun rises and sets today according to the unit s internal astronomical timeclock If this command is used on a GRX AV RS232 unit an error condition is issued Example RA CR...

Страница 28: ...Eye Timeclock software an error statement is reported The sequence can be restarted from this point by a super sequence resume command Example QP CR Stop super sequence at the current step QC Super S...

Страница 29: ...CRESTRON This page intentionally left blank Operations Guide Doc 5694 Lutron Interface 25...

Страница 30: ...CRESTRON This page intentionally left blank 26 Lutron Interface Operations Guide Doc 5694...

Страница 31: ...CRESTRON Operations Guide Doc 5694 Lutron Interface 27 This page intentionally left blank...

Страница 32: ......

Отзывы: