16X16 QuickMedia™ Matrix Switcher
Crestron
QM-MD16X16
Uploading and Upgrading
Crestron recommends using the latest programming software and that each device
contains the latest firmware to take advantage of the most recently released features.
However, before attempting to upload or upgrade it is necessary to establish
communication. Once communication has been established, files (for example,
programs or firmware) can be transferred to the control system (and/or device).
Finally, program checks can be performed (such as changing the device ID or
creating an IP table) to ensure proper functioning.
Establishing Communication
Use Crestron Toolbox for communicating with the QM-MD16X16; refer to the
Crestron Toolbox help file for details. There is a single method of communication:
indirect communication.
Indirect Communication
PC RUNNING
CRESTRON TOOLBOX
CONTROL SYSTEM
QM-MD16X16
SERIAL,
ETHERNET
OR USB
CRESNET
•
QM-MD16X16 connects to control system via Cresnet.
•
Establish communication between the PC and the control system as
described in the latest version of the 2-Series Control Systems Reference
Guide (Doc. 6256).
•
Use the Address Book in Crestron Toolbox to create an entry for the
QM-MD16X16 using the expected communication protocol (Indirect).
Select the Cresnet ID of the QM-MD16X16 and the address book entry of
the control system that is connected to the QM-MD16X16.
•
Display the QM-MD16X16’s “System Info” window (click the
icon);
communications are confirmed when the device information is displayed.
Programs and Firmware
Program or firmware files may be distributed from programmers to installers or from
Crestron to dealers. Firmware upgrades are available from the Crestron website as
new features are developed after product releases. One has the option to upload
programs via the programming software or to upload and upgrade via the Crestron
Toolbox. For details on uploading and upgrading, refer to the SIMPL Windows help
file or the Crestron Toolbox help file.
SIMPL Windows
If a SIMPL Windows program is provided, it can be uploaded to the control system
using SIMPL Windows or Crestron Toolbox.
Firmware
Check the Crestron website to find the latest firmware. (New users may be required
to register to obtain access to certain areas of the site, including the FTP site.)
Upgrade QM-MD16X16 firmware via Crestron Toolbox.
•
Establish communication with the QM-MD16X16 and display the “System
Info” window.
•
Select
Functions | Firmware…
to upgrade the QM-MD16X16 firmware.
20
•
16X16 QuickMedia™ Matrix Switcher: QM-MD16X16
Operations Guide – DOC. 6538A
Содержание QM-MD16X16
Страница 1: ...Crestron QM MD16X16 16X16QuickMedia MatrixSwitcher Operations Guide ...
Страница 4: ......