![Crestron DM-NVX-E760 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/crestron/dm-nvx-e760/dm-nvx-e760_product-manual_2684295015.webp)
Product Manual — Doc. 8918B
DM-NVX-E760 and DM-NVX-E760C • 11
The network switch port that connects to a DM NVX device must be enabled with IGMPv2 or
IGMPv3 snooping to prevent the switch from flooding the multicast destination address traffic
to all other connected ports. The multicast destination address that is configured for the DM
NVX device must be within the range of qualified addresses. An upstream device such as a layer
3 router or switch periodically sends the IGMP General Query messages to hosts in order to
maintain group membership state information. These queries can be either general or group-
specific queries. The host responds to queries with IGMP membership reports. The host running
IGMPv2 or IGMPv3 may also send a Leave Group message to routers or switches in order to
withdraw from the group.
NOTES:
l
DM NVX devices do not support random-timer and source-specific queries.
l
As a host, a DM NVX device configured for support of IGMPv3 is compatible with a
network switch (IGMP querier) that is configured for IGMPv2.
IGMP snooping switches build forwarding lists by listening for and, in some cases, intercepting
IGMP messages. Although the software processing the IGMP messages may maintain state
information based on the full IP group addresses, the forwarding tables are typically mapped to
link layer addresses as shown in the following example.
Example of Forwarding Table
Multicast MAC Address
Member Ports
01-00-5E-00-00-01
2, 7
01-00-5E-01-02-03
1, 2, 3, 7
01-00-5E-23-E2-05
1, 4
Because only the least significant 23 bits of the IP address are mapped to Ethernet addresses
(RFC 1112), there is a loss of information when forwarding solely on the destination MAC
address. For example, IP addresses 224.0.0.123 and 239.128.0.123 and similar IP multicast
addresses all map to MAC address 01-00-5e-00-00-7b for Ethernet. As a result, IGMP snooping
switches may collapse IP multicast group memberships into a single Ethernet multicast
membership group.
In addition to building and maintaining lists of multicast group memberships, the snooping
switch must also maintain a list of multicast routers. When multicast packets are forwarded, the
packets should be forwarded not only on ports that have expressed joins using IGMP but also on
ports to which multicast routers are attached.
NOTES:
l
Do not assign reserved multicast IP addresses to a DM NVX device for streaming. For
additional information, go to
https://www.iana.org/assignments/multicast-
addresses/multicast-addresses.txt
.
l
Multicast collision is a concern with IPv4. For example, multicast IPv4 addresses 224.8.7.6
and 229.136.7.6 translate to the same MAC address (01:00:5E:08:07:06).
Содержание DM-NVX-E760
Страница 27: ...Product Manual Doc 8918B DM NVX E760 and DM NVX E760C 23 Settings Tab Stream Custom DSCP ...
Страница 35: ...Product Manual Doc 8918B DM NVX E760 and DM NVX E760C 31 Settings Tab Inputs ...
Страница 38: ...34 DM NVX E760 and DM NVX E760C Product Manual Doc 8918B Settings Tab Port Selection DM NVX E760C Page Shown ...
Страница 46: ...42 DM NVX E760 and DM NVX E760C Product Manual Doc 8918B Settings Tab Auto Update ...
Страница 51: ...This page is intentionally left blank Product Manual Doc 8918B DM NVX E760 and DM NVX E760C 47 ...