DO
GUIDE
DM-XIO-DIR-80/DM-XIO-DIR-160
DigitalMedia™ XiO Director Virtual Switching Appliance
NOTE:
The MGMT port is used for management and monitoring of the DM-XIO-DIR hardware.
The MGMT port does not provide access to the DM-XIO-DIR software and is independent of
Ethernet ports 1–4.
NOTE:
Ethernet ports 1–4 provide access to the DM-XIO-DIR software and allow configuration of
the software. The ports are independent of each other and have different network settings.
Rear Panel Connections
DO
Configure the Device
Using the web interface, configure the DM-XIO-DIR software. To access the web interface, open a
web browser and then go to the IP address of any one of the connected Ethernet ports labeled 1–4.
NOTE:
By default, DHCP is enabled and each of the Ethernet ports labeled 1–4 is automatically
assigned a different IP address. If a DHCP server does not exist on the network, the IP address of
each of the four Ethernet ports defaults to a link-local address in the 169.254.
xxx.xxx
range (refer to
RFC 3927 for information about link-local addressing). The link-local address is different for each of
the four Ethernet ports. To find the IP address of any of the connected Ethernet ports (1-4), use the
Device Discovery Tool in the Crestron Toolbox™ software.
NOTE:
The Ethernet port that is being used to configure the DM-XIO-DIR software must be
accessible from the networks of the device running the web browser, the associated DM-NVX
devices, and the control system (if present).
To log in to the web interface, enter the user name and password. The default user name is
admin
,
and the default password is
admin
.
DO
Install the Device
The Crestron
®
DM-XIO-DIR-80 and DM-XIO-DIR-160 can be mounted into a rack. Each device
occupies 1U of rack space.
WARNING:
Do not lift the device using the front handles. The handles are designed to
assist in
pul
ling
the device from a rack.
Mount the device into a rack using four mounting screws (not included).
DO
Connect the Device
Connect the device as required for the application.
Front Panel Connections
DO
Check the Box
QTY PRODUCT
PART NUM.
1
Power Cord
2050011
100-240V~
2-4A 50/60Hz:
From ac
power outlet
SERVICE:
For factory
use only
1–4:
10BASE-T/100BASE-TX/
1000BASE-T Ethernet to
video or control network
For factory
use only
For factory
use only
MGMT:
10BASE-T/100BASE-TX/
1000BASE-T Ethernet to
management network