Professional Audio Distribution Processor
Crestron
CNX-PAD8A
Leading Specifications
The three tables after this paragraph provide a summary of leading specifications for
the CNX-PAD8A.
Leading Specifications of the CNX-PAD8A
SPECIFICATION
DETAILS
Power Requirements
24 VDC, 0.42 A, 10 W
Default NET ID
44
Crestron Application Builder
TM
Version 1.1 or later
1
SIMPL
TM
Windows
®
Version 2.00.18 or later
2
2-Series Control System Update
3
Version 1.000.CUZ or later
4
CNMSX-AV/PRO Update File
Version 5.12.57x.UPZ or later
5
CNRACKX/-DP Update File
Version 5.12.57w.UPZ or later
5
CEN/CN-TVAV Update File
Version 5.12.63v.UPZ or later
5
ST-CP Update File
Version 4.01.04s or later
5
Rack Space Required
2U high, 1U wide
Environmental Temperature Range
41
o
to 122
o
F (5
o
to 50
o
C)
Environmental Humidity
10% to 90% RH (non-condensing)
Dimensions & Weight
Height: 3.47 in (8.81 cm)
(without ears and feet)
Width: 17.10 in (43.43 cm)
Depth: 8.44 in (21.44 cm)
Weight: 5.16 lb (2.34 kg)
1
The product is supported in the Crestron Application Builder Software, both in the Residential and
Commercial versions. Contact Crestron Customer Service for licensing details.
2
The latest software versions can be obtained from the What's New page (SIMPL Windows) or
Downloads page (SIMPLWIN Library) of the Crestron website (
. New users are
required to register in order to obtain access to the FTP site.
For programming purposes, the CNX-PAD8A is completely substitutable for the CNX-PAD8.
3
Crestron 2-Series control systems include the AV2, AV2 with Card Cage, CP2, CP2E, PAC2,
PAC2M, PRO2, and RACK2.
4
Filenames for 2-Series control system update files have a CUZ extension and can be obtained from
the What's New page (Control Systems Update Files section) or Downloads page (OPSYS Library)
of the Crestron website.
5
CNX upgrade files are required for either CNMSX-AV/Pro or CNRACKX/-DP. Filenames for CNX
upgrade files have a UPZ extension and ST-CP files are in one EXE or zipped UPZ file. All can be
obtained from the What's New page (Control Systems Update Files section) or Downloads page
(OPSYS Library) of the Crestron website (
. Update files are specifically
designed for certain control systems. If an update file is loaded into a control system other than the
device for which it was intended, it may lockup the control system, which would then have to be
returned to Crestron. Update files with an "
S
" designator are for the ST-CP, "
V
" designator for
CEN/CN-TVAV, "
W
" for CNRACKX-DP, and "
X
" for CNMSX-AV/Pro control systems. Control
systems are able to recognize and reject incorrect update files. However, when updating control
systems, do not ignore Crestron Viewport warning prompts or messages.