Crestron
CLF-DIMRFB
infiNET
™
Lamp Dimmer
RUN Mode Functions (Continued)
EVENT ACTION
Foot switch is
pressed.
Toggle between the preset level and
OFF, using the following rule:
If load is currently OFF, recall preset,
otherwise turn load OFF.
SET
When the mode selection switch is in the “SET” position, it is operating
in the
SET
mode. The LED will blink to indicate that the dimmer is in the
SET
mode. Refer to the following table for a list of available functions
when the dimmer is operating in the
SET
mode.
NOTE
: Mode selection switch must be in the “SET” position for at least
0.5s for unit to enter
SET
mode.
SET Mode Functions
EVENT ACTION
SET mode entered
(from OFF or RUN
mode).
Set the load to the preset level using a
0s fade* (or the minimum allowed
fade).
LED will blink at a steady rate while in
this mode (refer to “LED Behavior” on
page 17.
Foot switch is
pressed.
Manually raise or lower the load using
the current “ramp time”* parameter.
The behavior will be alternating;
releasing the button and pressing it
again will cause the lights to ramp in
the opposite direction. Switch to “RUN”
mode to store preset.
(User can abort any changes made in
SET mode by switching unit OFF
before returning to RUN.)
* Fade time and ramp time are parameters that can be changed in SIMPL
Windows. Refer to the SIMPL Windows help file (F1) for details.
Operations Guide – DOC. 6479
infiNET
™
Lamp Dimmer: CLF-DIMRFB
•
15
Содержание CLF-DIMRFB
Страница 1: ...Crestron CLF DIMRFB infiNET LampDimmer Operations Guide...
Страница 4: ......