C2N-SDC Control Signals
SIGNAL TYPE AND NAME DESCRIPTION
Digital output:
<
Sh1_MoveCommanded
>
Indicates that Shade 1 has received an open or
close command (momentary, full or jog). The
output remains high until a stop command is
sent, or until <
Sh1_MaxTime
> or
<
Sh1_JogTime
> has expired.
The output will remain high if Shade 1 reaches
the upper or lower mechanical limit of travel
and has stopped, but the timers have not yet
expired.
High/1 = Shade 1 move commanded (timer not
expired); Low/0 = Shade 1 stopped (timer
expired, or Stop command sent, or Momentary
command released)
Digital input:
<
Sh1_OpenMomentary
>
Opens Shade 1 on the rising edge of the input,
and stops on release or when
<
Sh1_MaxTime
> expires.
High/1 (rising edge) = Open;
Low/0 (falling edge) = Stop
Digital input:
<
Sh1_CloseMomentary
>
Closes Shade 1 on the rising edge of the input,
and stops on release or when
<
Sh1_MaxTime
> expires.
High/1 (rising edge) = Close;
Low/0 (falling edge) = Stop
Digital input:
<
Sh1_OpenFull
>
Opens Shade 1 to the upper mechanical limit,
or until <
Sh1_MaxTime
> expires, on the rising
edge of the input.
High/1 (rising edge) = Open full;
Low/0 = No effect