Crestron
C2N-IRGW-F
IR
Gateway
NOTE:
To ensure proper operation, the C2N-IRGW-F should not be
painted.
Hardware Hookup
Make the necessary connection as called out in the illustrations that
follow this paragraph. Refer to “Network Wiring” on page 6 before
connecting the pigtail wires from the C2N-IRGW-F. Apply power after
the connection has been made.
When making the connection to the C2N-IRGW-F, use Crestron power
supplies for Crestron equipment.
Hardware Connection for the C2N-IRGW-F
Pigtail Wires from C2N-IRGW-F
CRESNET:
CONNECT
TO THE
CRESNET
CONTROL
NETWORK
Red (24 - Power)
White (Y - data)
Blue (Z - data)
Black (G - ground)
Universal Remotes
Any universal remote transmitting RC5 code (and some Sharp codes) can
communicate with the Crestron control system and allow the user to
select and activate any function in the control system. An RC5 code is 14
bits long. Each code includes a 5-bit address (or system) and a 6-bit
command. Sharp uses a different IR protocol, but some of their codes are
acceptable.
NOTE:
The Philips Pronto contains built-in RC5 commands for out-of-
the-box use.
Operations & Installation Guide – DOC. 6574A
IR Gateway: C2N-IRGW-F
•
9