Decorator Keypads
Crestron
C2N-DBF12 & C2N-DBN12
C2N-DBF12 & C2N-DBN12 Troubleshooting (Continued)
TROUBLE
POSSIBLE
CAUSE(S)
CORRECTIVE
ACTION
Keypad does
not function
(Continued).
Keypad Net ID is
the same as
another device’s
Net ID.
Assign a different Net
ID in SIMPL Windows
and reset unit using
Toolbox.
Feedback signal
names incorrect in
SIMPL Windows
program.
Verify SIMPL
Windows program for
feedback signal
names.
Button LED
does not
illuminate.
LED intensity set
to 0 (zero).
Set intensity to
desired level.
Pressing button
yields wrong
result.
Keypad is
mounted upside
down.
Check keypad
orientation.
Keypad
programmed
incorrectly.
Check programming
in SIMPL Windows.
Check Network Wiring
Use the Right
Wire
In order to ensure optimum performance over the full range of your
installation topology, Crestron Certified Wire, and only Crestron
Certified Wire, may be used. Failure to do so may incur additional
charges if support is required to identify performance deficiencies
because of using improper wire.
Calculate
Power
CAUTION:
Use only Crestron power supplies for Crestron equipment.
Failure to do so could cause equipment damage or void the Crestron
warranty.
CAUTION:
Provide sufficient power to the system. Insufficient power
can lead to unpredictable results or damage to the equipment. Please use
the Crestron Power Calculator to help calculate how much power is
needed for the system (
http://www.crestron.com/calculators
).
When calculating the length of wire for a particular Cresnet run, the wire
gauge and the Cresnet power usage of each network unit to be connected
must be taken into consideration. Use Crestron Certified Wire only. If
20
•
Decorator Keypads: C2N-DBF/N12
Operations & Installation Guide – DOC. 6200A