40 • AirMedia® Presentation Gateway
Security Reference Guide — Doc. 7693AC
integrate with Crestron 3-Series® control systems. When a Crestron control system is used,
lights, display, HVAC, shading, and virtually any other device in the room can be controlled.
Additionally, the control system can implement Simple Network Management Protocol (SNMP)
to integrate with existing IT management tools. The device parameters can be set and
monitored by a Crestron control system as shown in the following table.
Device Parameters
Name
Access
Type
Function
Status
Read
Analog
Reports the status of the device
Number of
Users
Connected
Read
Analog
Indicates the number of users currently connected
Device Access
Code
Read
Analog
Sets the device access code
NOTE:
The input sets the current code and is only
valid when the device code is in Fixed mode
(configured through the device's web
configuration).
Projector
Connected
Read/Write
Analog
Reports the status of a connected projector
Valid Values:
0 = Not connected
1 = Connected
Status Text
Read
Serial
Returns the status of the device as a string for
display
Device Parameters Table (Type Column) Key
Crestron Type
Standard Type
Digital
Boolean
Analog
16-bit integer
Serial
String (maximum length 255 bytes)
Crestron Fusion® software can also provide an alternative monitoring mechanism to SNMP. For
more information on Crestron Fusion software, refer to
Содержание AirMedia
Страница 1: ...AirMedia Presentation Gateway Security Reference Guide Crestron Electronics Inc ...
Страница 28: ...24 AirMedia Presentation Gateway Security Reference Guide Doc 7693AC AirMedia Screen for AM 200 and AM 300 ...
Страница 85: ...Security Reference Guide Doc 7693AC AirMedia Presentation Gateway 81 AirMedia for iOS AirMedia for Android ...
Страница 92: ...This page is intentionally left blank Security Reference Guide Doc 7693AC AirMedia Presentation Gateway 88 ...