4
CLASS 2 WIRING
OUTPUTS
100 -120V
220-240V
FUSE MUST BE CHANGED
FOR 100 -120V OPERATION,
TO T6.3AL/250V
FUSE MUST BE CHANGED
FOR 220-240V OPERATION,
TO T3.15AL/250V
50/60Hz
65 WATTS
Consumo de energia 65Wh
25V
4 Ohm
100V
COM
70V
(8) Fuse Holder
The fuse is located within the cap of the fuse holder. If the fuse fails, IT MUST BE REPLACED WITH THE SAME
TYPE AND VALUE NOTED FOR THE SELECTED LINE VOLTAGE IN ORDER TO AVOID DAMAGE TO THE
EQUIPMENT AND TO PREVENT VOIDING THE WARRANTY. If the amp repeatedly blows the fuse, it should be taken
to a qualified service center for repair.
WARNING: The fuse should only be replaced when the power switch is in the off position!
(9) Power Switch
This rocker switch applies mains power to the unit.
(10) Dual RCA Input Connector
A user accessible dual RCA input connector is available on channel 4. It provides an easy way to connect a local mono or
stereo unbalanced source to the WMA 4300. The Remote/Local selector switch must be pressed to activate this input.
(11) Remote/Local Selector Switch
Pressing this switch replaces the balanced euro input with the dual RCA jack for channel 4.
Installer Controls
HIGH
LOW
EQ
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
OFF
MAX
LINE OUT
MIN
MAX
+ _
G
MIX
CH. 4
INPUT
INPUTS
GAIN
MUTE
ALL
GAIN
THRESHOLD
MUTE
4
+ _
G
+ _
G
+ _
G
+ _
G
3
2
1
+48V
+48V
GAIN
12
13
14
15
17
19
21
20
21
16
18
22
18