background image

3

(1) ACL/Mute Indicator

This LED will illuminate red when the signal in the power amplifier reaches the point where the ACL circuit (Automatic 

Clip limiter) engages.  The ACL circuit reduces the gain automatically when necessary.  This indicator will also light 

whenever the “Mute All” input is activated.

(2) Amplifier Signal Indicator (SIG)

This LED  illuminates green to indicate signal presence at the amplifier. 

(3) Power Indicator

This LED illuminates when IPA is powered and active.

Front Panel

IPA 2300

POWER

SIGNAL

ACL/MUTE

PROFESSIONAL SERIES INSTALLATION POWER AMPLIFIER

TM

1

6

4

5

7

12

11

11

8

9

13

10

2

3

Rear Panel

LEVEL

CH. 2

(summed)

CH. 1

MIC

LINE

INPUTS

MUTE THRESHOLD

OFF

MAX

1

-80

0 dB

-1

-3

-6

-10

-15

-30

LEVEL

2

-80

0 dB

-1

-3

-6

-10

-15

-30

POWER

ON

50/60Hz

65 WATTS

Consumo de energia  65Wh

MADE IN CHINA

DESIGNED AND ENGINEERED IN U.S.A.

A PRODUCT OF CREST AUDIO INC.

5022 Hwy 493

MERIDIAN, MS 39305

100 -120V

220-240V

FUSE

100 -120V

T6.3AL/250V
220-240V

T3.15AL/250V

FUSE MUST BE CHANGED 

FOR 100 -120V OPERATION,

TO T6.3AL/250V  

 FUSE  MUST BE CHANGED

FOR 220-240V OPERATION, 

 TO T3.15AL/250V  

CLASS 2 WIRING

OUTPUTS

CAN-ICES-3(A)/NMB-3(A)

- - Apparatet må tilkoples jordet stikkontakt.
      (For Norway only)

- - Apparaten skall anslutas till jordat uttag.
     (For Sweden only)

- - Laite on liitettävä suojamaadoituskoskettimilla
      varustettuun pistorasiaan. (For Finland only) 

CAUTION

WARNING:

OR ELECTRIC SHOCK, THIS APPARATUS

LIQUIDS, SUCH AS VASES, SHOULD NOT

SHOULD NOT BE EXPOSED TO RAIN OR

MOISTURE AND OBJECTS FILLED WITH

TO PREVENT THE RISK OF FIRE HAZARD,

BE PLACED ON THIS APPARATUS.

REPLACE WITH SAME TYPE 250 VOLT FUSE.

TO REDUCE THE RISK OF FIRE

DANS LE BUT DE REDUIRE LES 

AVIS:

ELECTRIQUE, CET APPAREIL NE DOIT PAS

RISQUES D’INCENDIE OU DE DECHARGE 

ETRE EXPOSE A LA PLUIE OU A L’HUMIDITE

ET AUCUN OBJET REMPLI DE LIQUIDE, TEL

QU’UN VASE, NE DOIT ETRE POSE SUR 

CELUI-CI. REMPLACER PAR UN FUSIBLE DE 

MEME TYPE ET DE 250 VOLTS. 

AVIS:

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

This device complies with Part 15 of the FCC Rules.    

including interference that may cause undesired operation.   

(2) this device must accept any interference received,   

(1) this device may not cause harmful interference, and    

Operation is subject to the following two conditions:    

25V

4 Ohm

100V

IPA 2300

TM

COM

70V

- - Apparatets stikprop skal tilsluttes en stikkontakt med jord,
    som giver forbindelse til stkproppens jord. (For Denmark only)

+ _

G

MUTE ALL

FUSE

FUSE

(4) IEC Inlet Connector

This receptacle is for the IEC line cord (included) that provides AC power to the unit.
Please read this guide carefully to ensure your personal safety as well as the safety of your equipment.  Never break off 

the ground pin on any equipment.  It is provided for your safety.  If the outlet used does not have a ground pin, a 

suitable grounding adapter should be used and the third wire should be grounded properly.  To prevent the risk of 

shock or fire hazard, always be sure that the mixer and all other associated equipment are properly grounded.

(5) Fuse Holder

The fuse is located within the cap of the fuse holder. If the fuse fails, IT MUST BE REPLACED WITH THE SAME 

TYPE AND VALUE NOTED ON THE BACK OF THE UNITS FOR THE SELECTED LINE VOLTAGE IN ORDER TO 

AVOID DAMAGE TO THE EQUIPMENT AND TO PREVENT VOIDING THE WARRANTY. If the amp repeatedly 

blows the fuse, it should be taken to a qualified service center for repair.

Содержание IPA 2300

Страница 1: ...1 IPA 2300 Power Amplifer Owner s Manual...

Страница 2: ...is manual please let us know or check out our website at Web site http peaveycommercialaudio com products cfm cr Email techserve crestaudio com We are continuously looking for better ways to provide i...

Страница 3: ...SAME TYPE 250 VOLT FUSE TO REDUCE THE RISK OF FIRE DANS LE BUT DE REDUIRE LES AVIS ELECTRIQUE CET APPAREIL NE DOIT PAS RISQUES D INCENDIE OU DE DECHARGE ETRE EXPOSE A LA PLUIE OU A L HUMIDITE ET AUCUN...

Страница 4: ...d input impedance of channel 1 for microphone or line level applications Press in for line level input sources 11 Balanced Input Connector Input 1 The electronically balanced input will accept both li...

Страница 5: ...5 Block Diagram...

Страница 6: ...1 8 power Signal Noise 22 Hz 22 kHz typical All controls CCW 90 dB All controls nominal 12 00 85 dB Outputs Power Amplifier direct out 4 Ohms Power Amplifier transformer 25V 70 V 100 V Input Sensitivi...

Страница 7: ...h a rated output of 300 Watts The power switch shall be on the rear panel along with the detachable IEC cord fuse holder There shall be a Line Mic gain switch and Euro type connector for the channel 1...

Страница 8: ...ed only to equipment manufactured after 13 August 2005 www peaveycommercialaudio com Warranty registration and information for U S customers available online at www peaveycommercialaudio com warranty...

Отзывы: