The following is an example of a custom firing profile. To fire at a 300
°
F rise per hour up to 1600
°
F; at 108
°
F rise per
hour up to 1900
°
F with a five minute hold time and an alarm to sound at 1800
°
F, use these steps:
STEP PRESS
ACTION
DISPLAY / PROMPT
1
RAMP HOLD
Enters RAMP HOLD mode
USEr
2
Number (1-6)
Selects desired user file number
1
3
ENTER
Inputs user file number
SEGS
4
Number (1-8)
Selects number of firing segments
2
5
ENTER
Inputs number of segments
rA 1
6
Temperature (1-9999) 300
Selects temperature rate of rise
300
per hour for first segment
7
ENTER
Inputs rate of rise
°
F 1
8
Temperature (1-2350) 1600
Selects end temperature for first segment
1600
9
ENTER
Inputs end temperature for first segment
HLd 1
10
Time in hours and minutes 00.00 Selects hold time at end of first segment
00.00
11
ENTER
Inputs hold time for segment 1
rA 2
(zero for this example)
12
Temperature (1-9999) 108
Selects temperature rise rate (2nd segment) 108
13
ENTER
Inputs rate of rise
°
F 2
14
Temperature (1-2350) 1900
Selects end temperature for segment 2
1900
15
ENTER
Inputs end temperature for segment 2
HLd 2
16
Time in hours and minutes 00.05 Selects hold time at end of second segment 00:05
(five minutes for this example)
17
ENTER
Inputs hold time of five minutes
ALAr
for second segment
18
Temperature (1-9999) 1800
Selects temperature that alarm will sound 1800
19
ENTER
Inputs alarm temperature
CPLt
20
START
Starts the program in action
Before entering your custom program, create a chart to show the three components of each segment you wish to use. You
may have up to eight segments in your program, though you may choose to use fewer segments.
13