Cres Cor H137WSUA5DMFBC Скачать руководство пользователя страница 6

Insulated

Hot Cabinets

FL-2355-BC

Rev. 2 (12/20)

Page 6 of 8

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

5925 Heisley Road • Mentor, OH 44060-1833

OPERATING and MAINTENANCE INSTRUCTIONS

Model: H137 series Humidity Holding Hot Cabinet

BUC-EE’S PROGRAMMING REVISION J-08

REPLACEMENT PARTS:

120V

208V

240V

Blower Kit

0769-180-SS-K

0769-182-SS-K

0769-182-SS-K

Heater Kit, Air

2000W

0811-022-K

0811-185-K

0811-023-K

1470W

0811-019

Heater Kit, Water

1850W

0811-271

0811-278

0811-271

1500W

0811-314

High Limit (water pan)

0848-060

0848-060

0848-060

High Limit - 400°F

0848-033

0848-033

0848-033

Power Cord

2000W

0810-065-12-K

0810-039-07

0810-039-07

1500W

0810-029-06

Relay, Solid State

0857-136

0857-136

0857-136

Switch, Power

0808-125

0808-125

0808-125

Thermostat Control (Hot)

0848-092-40-K

0848-092-40-K

0848-092-40-K

Thermostat Control (Humidity)

0848-092-38-K

0848-092-38-K

0848-092-38-K

Thermostat Probe

0848-091-K

0848-091-K

0848-091-K

Terminal Block

0852-119

0852-119

0852-119

Transformer

0769-197

0769-197

0769-197

Vent Fan

0769-165

0769-174

0769-174

Water Pan Assembly

0756-037

0756-042

0756-037

Door, Complete  (Stainless Steel)

UA12/UA6/1834/1816 

1221-579-K

UA5

1221-597-K

Door, Gasket  (Stainless Steel)

UA12/UA6/1834/1816 

0861-185-K

UA5

0861-250-K

Door Hinge

0519-074-K

Door Latch

1006-122-01-K

Door Handle

0911-111

Handle, Side Pull

0911-087

Casters, 5”

0569-306-K

Casters, 5” w/brake

0569-306-BK

Wire Angles (Stainless Steel)

0621-281-SS-K

Pan Rack Insert Each (for -1834 Model)

1103-109

Clear Drip Pan

1017-058

Содержание H137WSUA5DMFBC

Страница 1: ...the switch on the light will come on NOTE The letters LOTPR Low Temperature will show on the control panel until it reaches 80 F 26 C 2 Push and hold knob for 5 seconds then turn to show 220 F Push th...

Страница 2: ...for 5 seconds then turn knob to desired humidity value setting Push the knob to set the value number 4 Preheat the cabinet for 1 2 hour 30 minutes NOTE This cabinet operates with air temperature prio...

Страница 3: ...for cleaning BEFORE CLEANING CABINET 1 Allow cabinet to cool 2 Do NOT hose cabinet with water 3 Do NOT get water on controls 4 Do NOT use abrasives or harsh chemicals WARNING DAILY MAINTENANCE WATER...

Страница 4: ...ng at cooking temps They are controlled by a thermal switch and may not kick on until unit has been operating for some time Call Toll free 877 CRES COR 273 7267 Fax 800 822 0393 www crescor com Convec...

Страница 5: ...SONNEL ONLY RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING TROUBLE SHOOTING CHART FAILURE POSSIBLE CAUSE 1 Switch light or control display does NOT light up 1a Circuit breaker fuse to wall outlet...

Страница 6: ...1500W 0810 029 06 Relay Solid State 0857 136 0857 136 0857 136 Switch Power 0808 125 0808 125 0808 125 Thermostat Control Hot 0848 092 40 K 0848 092 40 K 0848 092 40 K Thermostat Control Humidity 0848...

Страница 7: ...WATER HEATER HIGH LIMIT 300F t WATER PROBE AIR PROBE LOWER FLOAT SWITCH VENT FAN PROBE WIRES RUN DOWN OPPOSITE SIDE FRAME RAIL AS OTHER WATER PAN WIRES TB1 TRANSFORMER 2 1 4 3 1 2 3 4 5 6 5 6 8 7 7 8...

Страница 8: ...TCH UPPER FLOAT SWITCH VENT FAN ONE PIGGYBACK CONNECTOR USED ON TERMINAL BLOCK MUST BE PLACED ON MIDDLE TERMINAL FOR CLEARANCE 1 PROBE WIRES RUN DOWN OPPOSITE SIDE FRAME RAIL AS OTHER WATER PAN WIRES...