background image

Trendsetter NEWS SA

8

Trendsetter NEWS SA

Removing a Flyoff

8

9

b.  Rotate the two latches 

and lift the front panel.

Rotate the drum to expose 
the trailing-edge clamps.

Slide the trailing-edge clamps 
off the plate.

Fold over the corners 
of the plate.

Press the leading-edge 
clamps to free the plate.

Clean out any debris 
left behind.

In Print Console, click 

Resume

.

Reposition the trailing-edge clamps:

a.  Align the trailing-edge clamps.

b.  Slide the trailing-edge 

clamps into position.

* Refer to the 

Operator Guide

 for full details.

Open the front panel:

a.  In Print Console software, unlock 

the front panel.

3

4

5

6

7

The top panel opens 
automatically.

In Print Console, click 

Resume

.

11

10 Close the panels:

a.  Pull down the front panel and rotate 

the locking latches.

b.  Pull down the top panel, and then push on 

the two corners to lock the internal latches.

2

1

The device suspends activity.

CAUTION:

 Wear protective 

gloves when handling plates.*

!

CREO PRODUCTS LABEL

FABRICATION DRAWING

DESIGNED BY

PART NO.

SCALE

DOC

REV

SHEET

SIZE

OF

DRAWN BY

DATE

A

MILLIMETERS

UNLESS SPECIFIED

COPYRIGHT CREO PRODUCTS INC.

C

SP

REV

ECO

DRAWING CHANGES BY

DATE

APPROVED BY

2000:MAR:14

74-3260A

A

WARNING STRONG MAGNETIC FIELDS

1)  LABEL ADHESIVE:  3M 467 OR EQUIV.

2)  MATERIAL:               3M 7980 MATERIAL

3)  COLOUR:                  BLACK GRAPHICS ON BACKGROUND COLORS AS SHOWN

4) TOLERANCE:            +/-  1mm

5)  COMPUTER FILE AVAILABLE.

6)  LABEL TO BE CSA APPROVED - VENDOR ID MARK REQUIRED.

1:1

1

1

G. BEST

R. LEVASSEUR

A

D394

2000:MAR:14

GREG BEST

LABEL SPECIFICATIONS

WARNING!

AVERTISSEMENT!

WARNUNG!

STRONG

MAGNETIC

FIELDS

STARKES

MAGNETFELD

74-3260A-A

YELLOW (PANTONE 108C)

BACKGROUND AND EXCLAMATION MARK

WHITE BACKGROUND

CHAMPS

MAGNETIQUE

INTENSE

LABEL SIZE: 26.0mm x 31.0mm

2mm Rad. corners, typ.

CAUTION:

 If you have an implanted 

cardiac pacemaker, ensure that 
magnetic clamps are kept more 
than 7 cm (2.75 in.) away from the 
pacemaker.*

Содержание Trendsetter NEWS SA

Страница 1: ...www creo com Copyright 2005 Creo Inc All rights reserved Internal 732 00041A EN RevA Visual Quick Reference English 653 00979A EN A February 2005 Trendsetter NEWS SA...

Страница 2: ...Lights Operator Action Imaging Light Flashing green Wait the device is imaging a plate Load Light Flashing green Semi automatic mode load one or two plates for imaging OR Semi automatic mode wait the...

Страница 3: ...1 In Prinergy click OK to submit the le 1 In Brisque click Submit to submit the le 1 In Print Console click Open to submit the le 2 Right click the job and select Approve The output device receives t...

Страница 4: ...ess the Start button 8 Unload the media 4 Position media on the load ramp 3 Remove all slip sheets The load light ashes green The load light glows solid green Media alignment label The imaging light a...

Страница 5: ...trips 10 Clean Every three months Compressed air supply lters Six months or as needed 5 micron lter 4 Replace 0 01 micron lter 5 Replace Intake air lter 7 Replace Universal Debris Removal Cabinet UDRC...

Страница 6: ...Replace the O ring if necessary 6 Reattach the bowl by pushing it up and turning it to the right until it clicks Turn on the compressed air 90 psi 0 01 micron lter 4 Clean inside the bowl 5 Replace th...

Страница 7: ...ng each strip once in one direction only 4 2 3 2 3 Locate the blue plate roller Dampen a cloth with water and slide the cloth over the plate roller To close the panels a Pull down the front panel and...

Страница 8: ...ntake air lter from inside the fan box panel b Push the upper corners of the fan box panel in until you hear both latches click Intake air lter Part number 55 0700 Fan box panel 1 Clean the intake air...

Страница 9: ...Pull down the front panel and rotate the locking latches b Pull down the top panel and then push on the two corners to lock the internal latches 2 1 The device suspends activity CAUTION Wear protecti...

Отзывы: