background image

ZR Series with Cree SmartCast

®

 Technology 

Architectural Troffers with Removable Lens

Includes: ZR14™, ZR22™ and ZR24™

1 of 4

LPN00467X0003A0_B

INSTALLATION INSTRUCTIONS

INSTRUCTIONS D’INSTALLATION

TO INSTALL:

T- BAR CEILING MOUNTING 

STEP 1:

Install the (2) supplied T-Bar clips onto the 
mounting bracket on the outside of the housing. 
See 

Figure 1. 

STEP 2:

Bring the ZR troffer into the T-Bar Ceiling panel 
and attach the clips on the housing onto the 
T-Bar. 

STEP 3:

Attach the RF Module to the luminaire by 
clicking it into place as Shown in

 Figure 3.

1

Mounting Bracket

T-Bar Clips

ZR14™

ZR22™

ZR24™

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should 

always be followed including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant l’installation.

2.  This luminaire must be installed in accordance with the NEC or your 

local electrical code. If you are not familiar with these codes and 

requirements, consult a qualified electrician. 

Ce produit doit être installé conformément à NEC ou votre code 

électrique local. Si vous n’êtes pas familier avec ces codes et ces 

exigences, veuillez contacter un électricien qualifié.

3.  Do not handle energized module with wet hands or when standing on wet 

or damp surfaces, or in water.

4.  Suitable for damp locations.

Convient aux emplacements humides.

5.  Access above ceiling required. Do not install insulation within 3" (76mm) of 

any part of the luminaire. 

Accès requis au-dessus du plafond. Ne pas mettre l’isolant à moins de 76 
mm (3 po) de toute partie du luminaire.

SAVE THESE INSTRUCTIONS FOR 

FUTURE REFERENCE 

•  The ZR Series of recessed 

troffers is for non-insulated 

ceiling applications using 

T-Bar ceiling grid, drywall grid 

adaptors, and 

suspended mount. 

•  Designed for use in 120-

277V 50-60 Hz or 347V 60Hz 

protected circuit (fuse box, 

circuit breaker). Supply wire 

sized as per NEC or governing 

code(s), 90C rated.   

•  Make sure to cap off all unused 

leads.

•  ** Not intended for use with 

9/16” T-Bar grids unless used 

with a 9/16” accessory clip like 

“Armstrong® LFC- Fixture Clip” 

which can be purchased through 

distribution. Consult factory for 

non-standard grid applications.

•  Lens may shift during 

installation. Press center of 

lens to engage magnet strip 

after installation.

Содержание ZR14

Страница 1: ...rician Ce produit doit être installé conformément à NEC ou votre code électrique local Si vous n êtes pas familier avec ces codes et ces exigences veuillez contacter un électricien qualifié 3 Do not handle energized module with wet hands or when standing on wet or damp surfaces or in water 4 Suitable for damp locations Convient aux emplacements humides 5 Access above ceiling required Do not instal...

Страница 2: ...s blinking rapidly approximately 6 7 seconds See Figure 5 STEP 2 Release for 1 sec STEP 3 Press Hold RESET button for 0 5 sec Light will turn off for a few seconds then go to full bright and the Blue LED on the RF Module should begin a 2 blink sequence Figure 5 TROUBLESHOOTING Out of the box if the light does not turn on when power is applied Check Wiring with power off If wired correctly check to...

Страница 3: ...ired operation This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the device is operated in a commercial environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance w...

Страница 4: ...the cover of the junction box and bring in appropriate power supply to the junction box using one of the knock outs See Figure 3 STEP 2 Using customer supplied 90 C minimum rated wire connectors make the following electrical connections a Connect the black fixture lead to the voltage supply Line position Hot b Connect the white fixture lead to the neutral supply position c Connect the green or gre...

Отзывы: