background image

XSP Series

LED Street Light

Includes: XSPR™ Luminaires

INSTALLATION INSTRUCTIONS

1 of 2

CI379X20R3

TO INSTALL:

LUMINAIRE INSTALLATION

STEP 1: 

DO NOT 

remove splashguard from fixture. If 

mounting fixture to 1.25 IP pipe (1.66 O.D.), there 
is no need to modify the splashguard. If mounting 
fixture onto 2.0 IP pipe (2.38 O.D.), remove 
the knockout of the splashguard thru the rear 
opening of the fixture while the fixture is closed

.

STEP 2: 

To open cover, press tabs in on both sides of the 
cover and carefully let the cover swing down. 
Splashguard may dislodge from fixture, but 
should be repositioned once ready to mount. See 

Figure 1.

STEP 3: 

Slide fixture on to pole through opening on the 
rear of housing and through splashguard. See 

Figure 2.

STEP 4: 

Adjust leveling of fixture from side to side. To 
level from front to back, slide pole to different 
Adjustment Steps in upper housing. Each step 
changes the angle in 2.5° degree increments. 

STEP 5: 

Once desired position is achieved, tighten 
mounting bolts to the appropriate torque values 
specified in TORQUE VALUES table on the back 
of the sheet. See

 Figure 2

 (use 9/16" socket 

wrench).

STEP 6: 

IMPORTANT - DO NOT

 exceed these 

torque levels on the mount bolts. Exceeding 
recommended torque value resulting in excessive 
deformation of mounting bracket will cause 
stripping of mount hardware which could lead to 
an unsafe mounting condition.

STEP 7: 

Reference 

Electrical Connections

 section for 

completing electrical connections.

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed 

including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant l’installation.

2.  This luminaire must be installed in accordance with the NEC or your local electrical 

code. If you are not familiar with these codes and requirements, consult a qualified 

electrician. 

Ce produit doit être installé conformément à NEC ou votre code électrique local. 

Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un 

électricien qualifié. 

3.  If NEMA photo control is installed refer to NEMA Receptacle section for instructions.

4. 

If mounting bolts are completely removed in the field they should be hand threaded 

(prior to use of power tools) to ensure proper engagement of the thread when re-

installing. Failure to pre-start threads may result in cross-threading or stripping of the 

bolts during reinstallation.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

1

2

Cover Tabs

Mounting

Bracket

Pole

Mounting Bracket

Bolts 

Adjustment

Steps

TORQUE VALUES

Pipe

Size

Pipe Position

Bolt Torque

Required (in-lbs)

Bolt Torque

Required (N-m)

1.66 in O.D.

+5.0 degrees tilt

275

31

+2.5 degrees tilt

275

31

0 degrees (no tilt)

275

31

-2.5 degrees tilt

275

31

-5.0 degrees tilt

275

31

2.38 in O.D.

+5.0 degrees tilt

225

25

+2.5 degrees tilt

225

25

0 degrees (no tilt)

225

25

-2.5 degrees tilt

225

25

-5.0 degrees tilt

225

25

Содержание XSP Series

Страница 1: ...lectrical Connections section for completing electrical connections IMPORTANT SAFEGUARDS When using electrical equipment basic safety precautions should always be followed including the following READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1 DANGER Risk of shock Disconnect power before installation DANGER Risque de choc Couper l alimentation avant l installation 2 This luminaire must be installed in a...

Страница 2: ...ires into pole STEP 3 Close cover making sure that no wires are pinched and latches are fully engaged LINE OR HOT 1 GREEN LINE BLACK GROUND GREEN NEUTRAL WHITE DIM GREY DIM VIOLET NEUTRAL OR HOT 2 VIOLET GREY SUPPLY WIRING DIMMING OPTIONAL LUMINAIRE OPTIONAL NEMA CONTENT TERMINAL BLOCK DRV A B C D E F G H I DRV CRTL 1 2 3 4 5 NEMA RECEPTACLE OPTIONAL STEP 1 Rotational adjustment of the photo contr...

Страница 3: ...ción Conexiones eléctricas para llevar a cabo las conexiones eléctricas de especificaciones de la atenuación del producto MEDIDAS DE SEGURIDAD IMPORTANTES Al usar equipos eléctricos siempre se deben seguir precauciones de seguridad básicas incluidas las siguientes LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD 1 PELIGRO Riesgo de descarga eléctrica desconecte la alimentación antes de la instalaci...

Страница 4: ...je el exceso de cables de suministro hacia el interior del brazo PASO 3 Cierre la tapa asegurándose de no aplastar ningún cable y que los pestillos estén completamente enganchados LÍNEA O ENERGIZADO 1 VERDE LÍNEA NEGRO TIERRA VERDE NEUTRAL BLANCO ATEN GRIS ATEN MORADO NEUTRAL O ENERGIZADO 2 MORADO GRIS CABLEADO DE ALIMENTACIÓN LUMINARIA BLOQUE DE TERMINALES CONTENIDO NEMA OPCIONAL ATENUACIÓN OPCIO...

Отзывы: