XSP Series
LED Street Light
Includes: XSPR™ Luminaires
INSTALLATION INSTRUCTIONS
1 of 2
CI379X20R3
TO INSTALL:
LUMINAIRE INSTALLATION
STEP 1:
DO NOT
remove splashguard from fixture. If
mounting fixture to 1.25 IP pipe (1.66 O.D.), there
is no need to modify the splashguard. If mounting
fixture onto 2.0 IP pipe (2.38 O.D.), remove
the knockout of the splashguard thru the rear
opening of the fixture while the fixture is closed
.
STEP 2:
To open cover, press tabs in on both sides of the
cover and carefully let the cover swing down.
Splashguard may dislodge from fixture, but
should be repositioned once ready to mount. See
Figure 1.
STEP 3:
Slide fixture on to pole through opening on the
rear of housing and through splashguard. See
Figure 2.
STEP 4:
Adjust leveling of fixture from side to side. To
level from front to back, slide pole to different
Adjustment Steps in upper housing. Each step
changes the angle in 2.5° degree increments.
STEP 5:
Once desired position is achieved, tighten
mounting bolts to the appropriate torque values
specified in TORQUE VALUES table on the back
of the sheet. See
Figure 2
(use 9/16" socket
wrench).
STEP 6:
IMPORTANT - DO NOT
exceed these
torque levels on the mount bolts. Exceeding
recommended torque value resulting in excessive
deformation of mounting bracket will cause
stripping of mount hardware which could lead to
an unsafe mounting condition.
STEP 7:
Reference
Electrical Connections
section for
completing electrical connections.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed
including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. DANGER
- Risk of shock- Disconnect power before installation.
DANGER
– Risque de choc – Couper l’alimentation avant l’installation.
2. This luminaire must be installed in accordance with the NEC or your local electrical
code. If you are not familiar with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre code électrique local.
Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un
électricien qualifié.
3. If NEMA photo control is installed refer to NEMA Receptacle section for instructions.
4.
If mounting bolts are completely removed in the field they should be hand threaded
(prior to use of power tools) to ensure proper engagement of the thread when re-
installing. Failure to pre-start threads may result in cross-threading or stripping of the
bolts during reinstallation.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
1
2
Cover Tabs
Mounting
Bracket
Pole
Mounting Bracket
Bolts
Adjustment
Steps
TORQUE VALUES
Pipe
Size
Pipe Position
Bolt Torque
Required (in-lbs)
Bolt Torque
Required (N-m)
1.66 in O.D.
+5.0 degrees tilt
275
31
+2.5 degrees tilt
275
31
0 degrees (no tilt)
275
31
-2.5 degrees tilt
275
31
-5.0 degrees tilt
275
31
2.38 in O.D.
+5.0 degrees tilt
225
25
+2.5 degrees tilt
225
25
0 degrees (no tilt)
225
25
-2.5 degrees tilt
225
25
-5.0 degrees tilt
225
25