ELECTRICAL CONNECTIONS

STEP 1:

For 120-277V or 347-480V 

applications make the following Electrical 

Connections to the terminal block:

a.  Connect the black fixture lead to the voltage supply position 

of the terminal block.

b.  Connect the white fixture lead to the neutral supply position 

of the terminal block.

c.  Connect the green or green/yellow ground lead to the green 

wire position of the terminal block.

Dimming capabilities are accessible through the 

NEMA

®

 

receptacle 

when used with a photo control with dimming capabilities. 

STEP 2: 

Push excess supply wires into pole.

STEP 3: 

Close cover, making sure that no wires are pinched and latches are 
fully engaged. 

   LINE

OR HOT 1

GREEN

LINE-BLACK

GROUND-GREEN

NEUTRAL-WHITE