background image

3 of 5

LPN00630X0002A0_A

ADJUSTABLE ARM MOUNT- REQUIRES 

USE OF NTX-AA ACCESSORY

STEP 1:

Plug the female end of the quick connect, 
supplied with the trunnion, into the male 
connector on the luminaire. Make sure the two 
halves lock together. See 

Figure 1.

STEP 2:

Align the four holes in the upper adjustable 
arm with the four tapped holes in the luminaire 
housing. Attach the adjustable arm to the 
luminaire using the (4) 5/16” (8 mm) bolts and 
lockwashers supplied with the adjustable arm 
kit. Tighten bolts to 132 in-lbs (15 N

·

m). See 

Figure 7.

STEP 3:

Remove wiring compartment cover on 
adjustable arm by loosening (2) screws. See  

Figure 7.

STEP 4:

Feed supply leads up through the tenon that 
the luminaire will be mounted on.

STEP 5:

Route supply leads through open end of the 
adjustable arm and into wiring compartment.

NOTE:

 It may be necessary to disassemble 

the upper and lower portions of the adjustable 
arm in order to run the leads into the wiring 
compartment. If disassembly is necessary, 
remove the 3/8" (10 mm) bolt and lockwasher 
inside the wiring compartment and route leads 
into wiring compartment. See  

Figure

 

7. 

Reassemble upper and lower arm 

halves and replace 3/8" bolt and lockwasher. 
Do not tighten bolt at this time.

STEP 6:

Strain relief is required for electrical 
connections on slip fitter mounts at heights of 
25' (7.6 m) and above. Tie a knot in the supply 
leads above the hole where the leads enter 
the wiring chamber to reduce the strain on 

the connections. Make sure knot will not slip 
through opening in wiring compartment.

STEP 7:

Slip lower adjustable arm over 2 -3

/

8" (60 mm) 

O.D. heavy wall pipe or tenon making sure not 
to pinch any leads. Aim the luminaire in the 
proper direction and hand tighten all four Allen 
head set screws against outer wall of tenon. 
Hand tighten (4) screws against tenon. Once all 
four screws are hand tightened, secure them 
by tightening to 140 in-lbs (16 N

·

m).

STEP 8:

If 3/8" bolt holding the two halves of the 
adjustable arm together was not loosened in 
Step 5, loosen the bolt (DO NOT remove it) at 
this time.

STEP 9:

Tilt the luminaire to the desired angle and 
tighten the 3/8" (10 mm) bolt to 19 ft-lbs (25 
N

·

m) to lock the adjustable arm in place.

STEP 10:

Make the wiring connections inside the wiring 
compartment per the 

Electrical Connections 

section.

STEP 11:

Replace the wiring compartment cover that 
was removed in Step 3. Tighten screws to 30 
in-lbs (3.5 N

·

m).

ADJUSTABLE ARM MOUNT WITH 

BUTTON PHOTOCELL- REQUIRES USE 

OF NTX-AA ACCESSORY AND BUTTON 

PHOTOCELL

STEP 1:

Plug the female end of the quick connect, 
supplied with the trunnion, into the male 
connector on the luminaire. Make sure the two 
halves lock together. See 

Figure 1.

STEP 2:

Align the four holes in the upper adjustable 

arm with the four tapped holes in the luminaire 
housing. Attach the adjustable arm to the 
luminaire using the (4) 5/16” (8 mm) bolts and 
lockwashers supplied with the adjustable arm 
kit. Tighten bolts to 132 in-lbs (15 N

·

m). See 

Figure 7.

STEP 3:

Remove wiring compartment cover on adjustab 
le arm by removing (2) screws. See 

Figure 7.

STEP 4:

Feed supply leads up through the tenon that 
the luminaire will be mounted on.

STEP 5:

Route supply leads through open end of the 
adjustable arm and into wiring compartment.

NOTE:

 It may be necessary to disassemble 

the upper and lower portions of the adjustable 
arm in order to run the leads into the wiring 
compartment. If disassembly is necessary, 
remove the 3/8” (10 mm) bolt and lockwasher 
inside the wiring compartment and route leads 
into wiring compartment. See  

Figure 7.

 Reassemble upper and lower arm 

halves and replace 3/8” bolt and lockwasher. 
Do not tighten bolt at this time.

STEP 6:

Strain relief is required for electrical 
connections on slip fitter mounts at heights of 
25’ (7.6 m) and above. Tie a knot in the supply 
leads above the hole where the leads enter 
the wiring chamber to reduce the strain on 
the connections. Make sure knot will not slip 
through opening in wiring compartment.

STEP 7:

Slip lower adjustable arm over 2 -3

/

8” (60 mm) 

O.D. heavy wall pipe or tenon making sure 
not to pinch any leads. Aim the luminaire in 
the proper direction and hand tighten all four 
Allen head set screws against outer wall of 
tenon. Once all four screws are hand tightened, 
secure them by tightening them to 140 in-lbs 
(16 N

·

m).

6

 

 

 

 

 

7

Allowable 

Photocell Tilt 

Angle Rang

-45°

From 

Vertical

45°

From 

Vertical

Wiring 

Compartment 

Cover Plate

(2) Screws

Remove the Bolt at 

the Center Inside 

the Cover Plate to 

Separate the Two 

Halves

Tighten the Screws 

Here to Fix the 

Adjustable Arm on 

the Pole

Lower Half of the 

Arm to be Fixed on 

the Mounting Pole

Upper Arm to be 

Fixed on to the 

Luminaire Head 

using (4) bolts

Supply Leads

Button Photocell

Содержание NTF Series

Страница 1: ...R ACCESSORY STEP 1 Plug the female end of the quick connect supplied with the trunnion into the male connector on the luminaire Make sure the two halves lock together See Figure 1 STEP 2 Align the four holes in the inner trunnion with the four tapped holes in the luminaire housing Attach the trunnion to the luminaire using the 4 5 16 8 mm bolts and lockwashers supplied with the trunnion kit Tighte...

Страница 2: ...1 Plug the female end of the quick connect supplied with the trunnion into the male connector on the luminaire Make sure the two halves lock together See Figure 1 STEP 2 Position luminaire to be assembled to trunnion optic side down with mounting holes facing towards you IMPORTANT Trunnion with Twist Lock Photocell must be oriented with twist lock receptacle on the right side of the trunnion as vi...

Страница 3: ...tment per the Electrical Connections section STEP 11 Replace the wiring compartment cover that was removed in Step 3 Tighten screws to 30 in lbs 3 5 N m ADJUSTABLE ARM MOUNT WITH BUTTON PHOTOCELL REQUIRES USE OF NTX AA ACCESSORY AND BUTTON PHOTOCELL STEP 1 Plug the female end of the quick connect supplied with the trunnion into the male connector on the luminaire Make sure the two halves lock toge...

Страница 4: ...uminaire in the proper direction and hand tighten all four Allen head set screws against outer wall of tenon Once all four screws are hand tightened secure them by tightening them to 140 in lbs 16 N m STEP 9 If 3 8 bolt holding the two halves of the adjustable arm together was not loosened in Step 6 loosen the bolt DO NOT remove it at this time STEP 10 Tilt the luminaire to the desired angle and t...

Страница 5: ...ot installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAN ICES 005 A NMB 005 A ELECTRICAL CONNECTIONS STEP 1 Make the following Electrical Connections to supp...

Страница 6: ...ecteur mâle du luminaire Assurez vous que les deux moitiés se verrouillent ensemble Voir Figure 1 ÉTAPE 2 Alignez les quatre trous du tourillon interne avec les quatre trous taraudés du boîtier du luminaire Fixez le tourillon au luminaire à l aide des quatre 4 boulons de 8 mm 5 16 po et des rondelles de blocage fournis avec l ensemble du tourillon Serrez les boulons à 15 Nm 132 po lb Voir Figure 2...

Страница 7: ...ourillon dans le connecteur mâle du luminaire Assurez vous que les deux moitiés se verrouillent ensemble Voir Figure 1 ÉTAPE 2 Positionnez le luminaire à assembler au tourillon avec le côté optique vers le bas et les trous de montage orientés vers vous IMPORTANT Le tourillon avec la photocellule à verrou tournant doit être orienté avec le réceptacle du verrou tournant sur le côté droit du tourillo...

Страница 8: ...ÉTAPE 11 Replacez le couvercle du compartiment des fils retiré à l étape 3 Serrez les vis à 3 5 Nm 30 po lb MONTAGE DU BRAS RÉGLABLE AVEC PHOTOCELLULE À BOUTON NÉCESSITE L ACCESSOIRE NTX AA ET UNE PHOTOCELLULE À BOUTON ÉTAPE 1 Branchez l extrémité femelle du raccord rapide fourni avec le tourillon dans le connecteur mâle du luminaire Assurez vous que les deux moitiés se verrouillent ensemble Voir ...

Страница 9: ...u tenon d un mur robuste de 60 mm 2 3 8 po de diamètre extérieur en veillant à ne pas pincer les fils Orientez le luminaire dans la bonne direction et serrez les quatre vis à tête hexagonale contre la paroi extérieure du tenon Serrez à la main les 4 vis contre le tenon Une fois les quatre vis serrées à la main serrez les à 16 Nm 140 po lb ÉTAPE 9 Si le boulon de 10 mm 3 8 po maintenant les deux mo...

Страница 10: ...et utilisé selon le manuel d instructions peut causer une interférence nuisible aux communications radio L utilisation de cet équipement dans une zone résidentielle va sans doute causer une interférence nuisible où il sera requis que l utilisateur corrige l interférence à ses propres frais CAN ICES 005 A NMB 005 A RACCORDEMENTS ÉLECTRIQUES ÉTAPE 1 Effectuez les connexions électriques suivantes au ...

Отзывы: