![Cree NTA Series Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/cree/nta-series/nta-series_installation-instructions-manual_2682482002.webp)
2 of 8
LPN00631X0001A0_B
4
TRUNNION WITH BUTTON PHOTOCELL-
REQUIRES USE OF NTX-TR-PK
ACCESSORY AND BUTTON PHOTOCELL
NOTE:
Area lights are only designed for
mounting orientation from 0° (horizontal) to
45° tilt.
NOTE:
Area lights are not to be used as
uplights.
STEP 1:
Plug the female end of the quick connect,
supplied with the trunnion, into the male
connector on the luminaire. Make sure the two
halves lock together. See
Figure 1.
STEP 2:
Align the four holes in the front half of the
trunnion with the four tapped holes in the
luminaire housing. Attach the trunnion to the
luminaire using the (4) 5/16” (8 mm) bolts and
lockwashers supplied with the trunnion kit.
Tighten bolts to 132 in-lbs (15 N
·
m). See
Figure 4.
STEP 3:
Remove wiring compartment cover on trunnion
by loosening (2) screws. See
Figure 4.
STEP 4:
Remove the center knockout from the cover by
striking knockout with a hammer and punch.
STEP 5:
Remove the nut from the threaded nipple of
the photocell and insert the threaded nipple
of the photocell through the hole in the cover.
The body of the photocell and the o-ring on the
threaded nipple should remain on the inside
surface of the cover.
STEP 6:
Tighten the nut onto the exposed end of the
threaded nipple to secure the photocell to the
cover.
STEP 7:
Wire the photocell by following the wiring
instructions included with the photocell.
STEP 8:
Reattach the wiring compartment cover that
was removed in Step 3. Tighten the screws to
30 in-lbs (3.5 N
·
m).
NOTE:
Make sure no wires are pinched.
STEP 9:
Mount the luminaire in the desired location
using (2) 3/8” (10 mm) bolts (customer
supplied) appropriate for the mounting surface.
See
Figure 3.
STEP 10:
Make wiring connections to the cord leads per
the
Electrical Connections
section.
STEP 11:
Remove #10-24 positioning screws on both
sides of the trunnion.
STEP 12:
Loosen 5/16" (8 mm) hex head bolts located on
both sides of the trunnion.
STEP 13:
Rotate trunnion to desired tilt angle. Line up
inner and outer trunnion positioning holes.
STEP 14:
Insert one #10-24 screw, removed in Step
11, into matching holes of inner and outer
trunnions. Tighten screw to 30 in-lbs (35 N
·
m).
Repeat with screw on opposite side of trunnion.
STEP 15:
Tighten both 5/16” hex head bolts on opposite
sides of the trunnion to 132 in-lbs (15 N
·
m).
TRUNNION WITH TWIST-LOCK
PHOTOCELL- REQUIRES USE OF NTX-
TR-3R ACCESSORY AND TWIST-LOCK
PHOTOCELL
NOTE:
Area lights are only designed for
mounting orientation from 0° (horizontal) to
45° tilt.
NOTE:
Area lights are not to be used as
uplights.
STEP 1:
Plug the female end of the quick connect,
supplied with the trunnion, into the male
connector on the luminaire. Make sure the two
halves lock together. See
Figure 1.
STEP 2:
Position luminaire to be assembled to trunnion
optic side down with mounting holes facing
towards you.
IMPORTANT:
Trunnion with Twist Lock
Photocell must be oriented with twist lock
receptacle on the right side of the trunnion as
viewed from behind luminaire.
STEP 3:
Align the four holes in the inner trunnion with
the four tapped holes in the luminaire housing.
Attach the trunnion to the luminaire using
the (4) 5/16” (8 mm) bolts and lockwashers
supplied with the trunnion kit. Tighten bolts to
132 in-lbs (15 N
·
m). See
Figure 5.
STEP 4:
Mount the luminaire in the desired location
using (2) 3/8” (10 mm) bolts (customer
supplied) appropriate for the mounting surface.
See
Figure 3.
STEP 5:
Make wiring connections to the cord leads per
the
Electrical Connections
section.
STEP 6:
Remove #10-24 positioning screws on both
sides of the trunnion.
STEP 7:
Loosen 5/16" (8 mm) hex head bolts located on
both sides of the trunnion.
STEP 8:
Rotate trunnion to desired tilt angle. Line up
inner and outer trunnion positioning holes.
STEP 9:
Insert #10-24 screw, removed in Step 6, into
matching holes of inner and outer trunnion.
Tighten screw to 30 in-lbs (35 N
·
m). Repeat
with screw on opposite side of trunnion.
STEP 10:
Tighten both 5/16” hex head bolts on opposite
sides of the trunnion to 132 in-lbs (15 N
·
m).
STEP 11:
Twist lock receptacle must be positioned
to orient photocell b/- 45° from
vertical. See
Figure 6
. If the receptacle needs
to be repositioned to orient photocell in this
tilt range, remove the screws holding the
receptacle mounting bracket to the trunnion
(See
Figure 5
), and reposition mounting
bracket to properly orient receptacle. Retighten
screws to 30 in-lbs (3.5 N
·
m) after repositioning
bracket.
STEP 12:
Install twist lock photocell.
5
Wiring
Compartment
Cover
(2) Screws
Button Photocell
Mounting Bracket
of the Trunnion
Front Half of Mounting
Arm. Fix this to the
Luminaire Head
For Wall Mounting,
Keep the Keyholes
Facing Upwards During
Installation
Mounting Arm Fix this
to the Luminaire Head
using (4) Bolts
Rear Trunnion
Bracket. Fix this
to the Mounting
Surface
(2) Adjustment
Screws for Twist
Lock Receptacle
(One Each Side of
Twist Lock)
Twist Lock
Photocell
Receptacle
For Wall Mounting,
Keep the Keyholes
Facing Upwards During
Installation
#10-24 Screws
to Adjust the
Orientation
(2) 5/16"
(8 mm)
Bolts
#10-24 Screws
to Adjust the
Orientation
(2) 5/16"
(8 mm)
Bolts