IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant l’installation

2.  This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these 

codes and requirements, consult a qualified electrician.

Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes 

et ces exigences, veuillez contacter un électricien qualifié.

3.  These luminaires are thermally protected. Do not install insulation within 3 inches (76 mm) of luminaire sides or junction box nor 

above luminaire in such a manner as to entrap heat.

Ne pas mettre l’isolant a moins de 76 mm (3 po) de toute partie du luminaire. Convient aux plafonds suspendus.

4.  Blinking of this thermally protected luminaire may indicate overheating.

Si l’ampoule de ce luminaire a protection thermique clignote, cela peut signifier une surchauffe.

5.  This luminaire must be supported by main runners or other building structure that is capable of supporting luminaire weight.

6.  Do not mount near gas or electric heaters.

7.  Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized 

personnel.

8.  The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

9.  Do not use this equipment for other than its intended use.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

STEP 1

•  Mark a spot on the ceiling to indicate the 

luminaire location.

•  Use this mark as a center point and scribe a 

6-1/2" diameter circle on the ceiling and cut 

hole using proper cutting tool.

NOTE:

 Cut a 5-1/8" (for 4" luminaire ), 

8-1/16" (for 8" luminaire) opening.

STEP 2

•  Remove cable tie from the LED engine 

before installation.

STEP 3

•  This luminaire is provided with universal 

mounting brackets that accept the following 

mounting means: C-Channels, flat bar

hangers, ¾” and 1-1/2” lathing, or ½” 

conduit (order mounting means separately).

•  Install selected mounting means through 

the universal mounting bracket.

STEP 4

•  From above ceiling, position luminaire so 

that the trim opening of the housing fits 

inside the hole cut in the ceiling.

STEP 5

•  Secure the C-channels, conduit or bar 

hangers to the ceiling structure in such 

a way to provide sufficient support to 

the luminaire as well as to prevent the 

luminaire from moving up.

NOTE:

 T-bar clips may be purchased 

separately using accessory part number 

RARC7.

STEP 6

•  Adjust the plaster ring by loosening wing 

nuts located on each of the hanging 

brackets. See 

Figure 1

.

STEP 7

•  Raise or lower the luminaire so that the 

plaster ring is flush with or no more than 

1/16” above the ceiling finished surface. See 

Figure 2.

•  Tighten wing nuts.

NOTE:

 Luminaire may be adjusted to 

accommodate ceiling thickness up to 1-3/8" 

thick.

STEP 8

•  Make the appropriate electrical connections 

per the E

lectrical Connections Section

 on 

the last page..

LUMINAIRE INSTALLATION

1

2

Wiring Nut

Universal Mounting 

Bracket

Fished Ceiling 

Structure

Plaster Frame

Отзывы: