background image

1 of 2

CI088X03R4

Cree Edge

™ 

LED Area Round Post Top Mount

Includes: ARE-EDR-R3, R4, R5

INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always 

be followed including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  To reduce the risk of electrical shock, turn off power supply before 

installation or servicing.

2.  This luminaire must be installed in accordance with the NEC or your 

local electrical code. If you are not familiar with these codes and 

requirements, consult a qualified electrician. 

SAVE THESE INSTRUCTIONS FOR FUTURE 

REFERENCE

NOTES:

1. 

This carton contains complete fixture and fitter assembly.

2. 

Tenon mount fixtures used on aluminum or reinforced fiberglass poles 

must be mounted on 3” (77 mm) O.D. tenons.

3.  Tenon mount set screws should be tightened to 120 in-lbs (13 N-m)

TO INSTALL:

TENON MOUNT

STEP 1:

Remove hub cover located at the top of the hub by removing the two Phillips 
screws. See 

Figure 1

.

STEP 2: 

Feed supply conductors through base of hub. Strain relief may be provided by 
tying a knot in conductors.

STEP 3: 

Slid hub over the tenon (2-3/8 to 3") of pole until hub is resting on top of 

tenon.

STEP 4: 

Secure fixture to pole tenon by tightening the 3/8" set screws. Tighten set 
screws by alternating from one side of the hub to the other, following the 
cross pattern tightening method in 

Figure 2

, until all set screws have been 

tightened to 120 in-lbs (13 N-m). 

STEP 5: 

Replace hub cover from Step 1 after completing electrical connections 
section.

DIRECT MOUNT TO 5" ROUND POLE

STEP 1:

Remove hub cover located at the top of the hub by removing the two Phillips 
screws. See 

Figure 1.

STEP 2: 

Feed supply conductors through base of hub. Strain relief may be provided by 
tying a knot in conductors.

STEP 3: 

Slide hub into 5 inch pole until hub is resting on top of pole. 

STEP 4: 

Secure fixture to pole by tightening the center mounting bolt to  
140 in.lbs (16N•m).

STEP 5: 

Replace hub cover from Step 1 after completing electrical connections 
section.

1