background image

CR24 UPKIT 

1

2b

1b

INSTALLATION INSTRUCTIONS

CR24 UPKIT

PREPARE LIGHT ENGINE FOR INSTALLATION

Step 1: 

a. Slide Outer Adapter Mount up around the 

Driver Enclosure on the Light Engine. 

b. Install the Inner Adapter Mount by sliding it 

along the Light Engine Reflector making sure 

that the guide rail on the Inner Adapter enters 

the guide slot on the Outer Adapter. Also 

ensure that the flange on the Light Engine 

glides into the flange slot on the Inner Adapter 

Mount. Once together, verify that the snap tabs 

are fully engaged in the tab holes.

c. Repeat the steps on the other end of the 

Light Engine that doesn’t have the Driver 

Enclosure.

PREPPING THE HOST LIGHTING FIXTURE

Step 2: 

a. Disconnect power to the host lighting fixture 

to be replaced.

b. Remove the Lens/Louver, Fluorescent Light 

Bulbs, Lamp Holders, Lamp Holder Leads and 

Ballast Cover from lighting fixture.

TO INSTALL:

1a

CR24-UPKIT Includes:

(2) Ground Wire Assembly (5) Mount Plugs

(2) Outer Adapter Mount

(2) Inner Adapter Mount

(2) End Mounts

(2) Side Panels

(1) Light Engine 

(Packaged Separately)

NOTICE: Do not install with total power input greater 

than power rating of original fixture. 

WARNING – Risk of fire or electric shock. LED 

Retrofit Kit installation requires knowledge of 

luminaires electrical systems. If not qualified, do not 

attempt installation. Contact a qualified electrician.

WARNING – Risk of fire or electric shock. Install this 

kit only in the luminaires that have the construction 

features and dimensions shown in the photographs 

and/or drawings. Do not make or alter any open 

holes in an enclosure of wiring or electrical 

components during kit installation.

WARNING – To prevent wiring damage or abrasion, 

do not expose wiring to edges of sheet metal or 

other sharp objects.

NOTICE: This kit is intended for use with existing 

light fixtures where the host light fixture is either 

(a) provided with no open holes larger than 26mm

(0.04in

2

) in area, or (b) rated, and marked, for use in 

non-fire rated installations.

NOTE: Suitable for bi-level switching only on line 

voltage input for low voltage dimming connections, 

Class 1 wiring methods shall be employed. 

NOTE: This kit is intended for use with existing light 

fixtures with standard 2’ width, 4’ length and an 

internal height of minimum 3”.

NOTE: This retrofit is suitable for use in Type IC 

applications.

Light Engine Flange

Tab Holes

Guide Slot

Guide Rail

Flange Slot

Snap Tabs

1b

Fluorescent

 Light Bulbs

Lens/Louver

Lamp Holder

Ballast

Lamp 

Holder Leads

Ballast Cover