FCC NOTICE
CAUTION:
Changes or modifications not expressly approved could void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
CAN ICES-005 (A)/NMB-005 (A)
ELECTRICAL CONNECTIONS
STEP 1:
Make the following Electrical Connections to the terminal block:
a. For 120 V /277 V / 347 V connect the supply Vin lead to the voltage
supply position of the terminal block (Hot 1 for
208 V /240 V / 480 V wiring).
b. For 120 V /277 V / 347 V connect the supply common lead to the
neutral supply position of the terminal block or (Hot 2 for
208 V /240 V / 480 V wiring).
c. Connect the green or green/yellow ground lead to the green wire
position of the terminal block.
Dimming capabilities are accessible through the
NEMA
®
receptacle
when used with a photo control with dimming capabilities.
STEP 2:
Push excess supply wires into pole.
STEP 3:
Close cover, making sure that no wires are pinched and latches are
fully engaged.
LINE
OR HOT 1
GREEN
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
NEUTRAL
OR HOT 2
SUPPL
Y WIRING
LUMINAIRE
TERMINAL
BLOCK