STEP 1:

Slide fixture on to a minimum 8” long tenon, 
through opening on the rear of housing. See 

Figure 1. 

STEP 2:

Once desired position is achieved, open cover 
by holding fixture and loosen the captive 
D-ring and allow the cover to swing open. See 

Figure 2 and 3.
NOTE 

Maximum assembly torque value for 

D-ring installation is 45 in-lbs (5 N

·

m).

STEP 3:

To level fixture, use bubble level located 
inside housing. Adjust leveling of fixture from 
side to side by rotating fixture on tenon. To 
level from front to back, slide pole in or out 
to different step in upper housing. Each step 
changes the angle in 2.5

°

 increments 

STEP 4:

NOTE:

 When tightening bolts make sure 

to alternate between bolts to keep bracket 
straight.

NOTE:

 TRVLG and TRVXL luminaires ordered 

with 4BLT option will have (2) mounting 
brackets and (4) mounting bolts.
Tighten mounting bolts to the appropriate 
torque values specified in TORQUE VALUES 
table on page 2. See 

Figure 1

 (use 9/16” 

socket wrench).

STEP 5:

Reference 

Electrical Connections

 section for 

completing electrical connections.

2

3

Adjustment

Steps

Mounting

Bracket

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be 

followed including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant l’installation.

2.  This luminaire must be installed in accordance with the NEC or your local 

electrical code. If you are not familiar with these codes and requirements, 

consult a qualified electrician. 

Ce produit doit être installé conformément à NEC ou votre code électrique 

local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez 

contacter un électricien qualifié. 

3.  If NEMA

®

 photo control is installed refer to NEMA

®

 Receptacle section for 

instructions.

4. 

If mounting bolts are completely removed in the field they should be hand 

threaded (prior to use of power tools) to ensure proper engagement of the 

thread when re-installing. Failure to pre-start threads may result in 

cross-threading or stripping of the bolts during reinstallation.

SAVE THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

D-ring

Mounting Bracket Bolts

1

•  Prior to installation, store luminaire in a dry location 

protected from rain, dust, and outdoor environment.  
If equipped with a photocell receptacle, do not store 
or install luminaire outdoors without immediately 
installing a suitable photocell, shorting cap, or other 
compatible device. Do NOT leave receptacle open to 
environmental elements.  Luminaires with a top-
mounted photocell receptacle should not be installed in 
an up-light position or at a tilt greater than 45 degrees 
from the down-light position.

•  This product must be installed in accordance with the 

applicable installation code by a person familiar with 
the construction and operation of the product and the 
hazards involved.

Importer: IDEAL PRODUCTS DISTRIBUTION DE MEXICO S. 
DE R.L. DE C.V.
Address:   Paseo de los Adobes, 1079, no. 10, Colonia 
Guadalajara Technology Park, C.P. 45010

Содержание Traveyo Series

Страница 1: ...GER Risque de choc Couper l alimentation avant l installation 2 This luminaire must be installed in accordance with the NEC or your local electrical code If you are not familiar with these codes and r...

Страница 2: ...pecification sheet for lumen and power multipliers for each field adjustable output dim setting STEP 1 The Dimming module is located inside the luminaire Open the cover by loosening the captive D ring...

Страница 3: ...adio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAN...

Страница 4: ...W ZZ TRVSM A HT 4ME 5L XXXX UL ZZ N W ZZ TRVSM A HT 5ME 5L XXXX UL ZZ N W ZZ TRVMD A HT 2ME 8L XXXX UL ZZ N W ZZ 120 277 Max 0 53 50 60 57 8000 140 2700 3000 4000 5700 150000 20 TRVMD A HT 3ME 8L XXXX...

Страница 5: ...X UL ZZ N W ZZ TRVXL A HT 4ME 25L XXXX UL ZZ N W ZZ TRVXL A HT 5ME 25L XXXX UL ZZ N W ZZ TRVXL A HT 2ME 27L XXXX UL ZZ N W ZZ 120 277 Max 1 69 50 60 182 27500 140 2700 3000 4000 5700 150000 20 TRVXL A...

Страница 6: ...Z TRVMD A HT 4ME 10L XXXX UH ZZ N W ZZ TRVMD A HT 5ME 10L XXXX UH ZZ N W ZZ TRVLG A HT 2ME 13L XXXX UH ZZ N W ZZ 347 480 Max 0 30 50 60 96 13000 140 2700 3000 4000 5700 150000 20 TRVLG A HT 3ME 13L XX...

Страница 7: ...ZZ N W ZZ TRVXL A HT 5ME 25L XXXX UH ZZ N W ZZ TRVXL A HT 2ME 27L XXXX UH ZZ N W ZZ 347 480 Max 0 58 50 60 182 27500 140 2700 3000 4000 5700 150000 20 TRVXL A HT 3ME 27L XXXX UH ZZ N W ZZ TRVXL A HT 4...

Страница 8: ...i n el ctrica antes de la instalaci n DANGER Risk of shock Disconnect power before installation 2 Esta luminaria debe instalarse de acuerdo con el C digo El ctrico Nacional NEC por sus siglas en ingl...

Страница 9: ...circuito proporcionado por el cliente en el recept culo PASO 3 Gire firmemente el control fotoel ctrico con su celda fotoel ctrica apuntando aproximadamente en direcci n norte N Algunos controles foto...

Страница 10: ...rferencias perjudiciales en cuyo caso el usuario deber corregir dicha interferencia por su propia cuenta CAN ICES 005 A NMB 005 A CONEXIONES EL CTRICAS PASO 1 Realice las siguientes conexiones el ctri...

Страница 11: ...X UL ZZ N W ZZ TRVSM A HT 4ME 5L XXXX UL ZZ N W ZZ TRVSM A HT 5ME 5L XXXX UL ZZ N W ZZ TRVMD A HT 2ME 8L XXXX UL ZZ N W ZZ 120 277 Max 0 53 50 60 57 8 000 140 2 700 3 000 4 000 5 700 150 000 20 TRVMD...

Страница 12: ...ME 25L XXXX UL ZZ N W ZZ TRVXL A HT 4ME 25L XXXX UL ZZ N W ZZ TRVXL A HT 5ME 25L XXXX UL ZZ N W ZZ TRVXL A HT 2ME 27L XXXX UL ZZ N W ZZ 120 277 Max 1 69 50 60 182 27 500 140 2 700 3 000 4 000 5 700 15...

Страница 13: ...H ZZ N W ZZ TRVMD A HT 4ME 10L XXXX UH ZZ N W ZZ TRVMD A HT 5ME 10L XXXX UH ZZ N W ZZ TRVLG A HT 2ME 13L XXXX UH ZZ N W ZZ 347 480 Max 0 30 50 60 96 13 000 140 2 700 3 000 4 000 5 700 150 000 20 TRVLG...

Страница 14: ...5ME 27L XXXX UH ZZ N W ZZ TRVXL A HT 2ME 30L XXXX UH ZZ N W ZZ 347 480 Max 0 65 50 60 219 30 000 140 2 700 3 000 4 000 5 700 150 000 20 TRVXL A HT 3ME 30L XXXX UH ZZ N W ZZ TRVXL A HT 4ME 30L XXXX UH...

Страница 15: ...RVSM A HT 5ME 5L XXXX UL ZZ N W ZZ TRVMD A HT 2ME 8L XXXX UL ZZ N W ZZ XI100C110V143BSY1 120 277 Max 0 94 114 0 95 10 Max 143 1 1 100 TRVMD A HT 3ME 8L XXXX UL ZZ N W ZZ TRVMD A HT 4ME 8L XXXX UL ZZ N...

Страница 16: ...T 3ME 25L XXXX UL ZZ N TRVXL A HT 4ME 25L XXXX UL ZZ N TRVXL A HT 5ME 25L XXXX UL ZZ N TRVXL A HT 2ME 27L XXXX UL ZZ N XI220C105V210CNA1 120 277 Max 2 1 245 0 95 15 Max 210 1 05 220 TRVXL A HT 3ME 27L...

Страница 17: ...4ME 10L XXXX UH ZZ N W ZZ TRVMD A HT 5ME 10L XXXX UH ZZ N W ZZ TRVLG A HT 2ME 13L XXXX UH ZZ N W ZZ XH150C105V140CNF 1 347 480 Max 0 5 167 0 95 15 Max 142 1 05 150 TRVLG A HT 3ME 13L XXXX UH ZZ N W ZZ...

Страница 18: ...XL A HT 4ME 25L XXXX UH ZZ N W ZZ TRVXL A HT 5ME 25L XXXX UH ZZ N W ZZ TRVXL A HT 2ME 27L XXXX UH ZZ N W ZZ XH220C105V210CNA 1 347 480 Max 0 71 245 0 95 10 Max 210 1 05 220 TRVXL A HT 3ME 27L XXXX UH...

Страница 19: ...ura o recibo o comprobante en el que consten los datos espec ficos del producto objeto de la compraventa junto con el producto en el establecimiento en que fue adquirido o en el nombre y domicilio del...

Отзывы: