Disassembly Instructions
Power Supply (PS)
For End User (EU)
PS
-
EU forSYS
-
B:
a.Follow the points: A
-
B
-
C
-
D of the instructions in para-
graph PS
-
CA
c.Disconnect the remaining cables connected to the luminaire
body if any (NEMA, Zhaga)
d.Hold the driver still and unscrew the fixing screws 19
e.Insert the new driver by screwing the fixing screws 19
f.
Reconnect the disconnected cables at points "a" and "b" (see
attached wiring diagrams)
g.Lower the support rod 17 while holding the door up
h.Close the door and screw the 6 screws to a torque of 2 Nm
For Control Authority
(CA)
PS
-
CA
A.Unscrew 6 screws to open the wiring compartment
B.Secure the door with the appropriate support rod 17
C.Disconnect the ground cable from the LED bar on the
heatsink 7 from connector 15
D.Disconnect the line and neutral cables from the led plate on
the heatsink 7 from the driver terminal block 16 using a
screwdriver
E.Disconnect the remaining cables connected to the driver on
your terminal block 16 with a screwdriver
F.Hold the driver in place and unscrew fixing screws 18 (for
SYS
-
A
-
#) or 19 (for SYS
-
B
-
#)
G.Extract the driver
19
16
N° DOC: DI122RLER0
Rev: 01
Latest Release Date: 18/11/2021
Disassembly Instructions
End of Life (EL)
Light Source (LS)
Follow instructions in the paragraph LS
-
CA
Power Supply (PS)
Follow instructions in the paragraph PS
-
CA
15