![CREE LIGHTING Cadiant Experience Dynamic Skylight Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/cree-lighting/cadiant-experience-dynamic-skylight/cadiant-experience-dynamic-skylight_installation-instructions_2682520002.webp)
2 of 3
LPN00647X0001A0_D
T-BAR CEILING INSTALLATION
NOTE:
For secondary bracing
(recommended), locate tabs on the side of
the luminaire for safety wire hangers. See
Figure 2
.
NOTE: DO NOT LAY THE CADI ANT™
DYNAMIC SKYLIGHT DOWN ON THE
SENSOR.
STEP 1:
Unpack the Cadiant™ Dynamic Skylight
from its shipping container being careful of
the sensor and not pinching the sidewalls.
STEP 2:
Bring the Cadiant™ Dynamic Skylight into
the T-Bar Ceiling panel and attach the
retention clips on the housing onto the T-Bar.
See
Figure 2
.
NOTE:
To maintain the Cadiant™ Dynamic
Skylight
experience,
ensure that the
sensor on luminaire is oriented as close
as possible to north. See
Figure 2 and
3
. For multiple luminaire installation, all
luminaires need to be facing the same
direction, with the sensor oriented as close
as possible to north.
NOTE:
Ensure luminaries are securely
fastened to ceiling framing member by
mechanical means identified for use with
the luminaire and ceiling member type in
accordance with the NEC revision currently in
place with the Authority Having Jurisdiction
(AHJ) over the locale of the installation.
STEP 3:
Remove the wiring access panel by
removing the one Phillips head screw. See
Figure 2
.
STEP 4:
Locate the RFM Module in the module
compartment and plug the module into
the RFM port located in the module
compartment. See
Figure 2
.
STEP 5:
Connect input conduit to access plate and
make wiring connections per the
Electrical
Connection
section.
STEP 6:
Push all wires back into the luminaire.
Re-secure cover with the provided Phillips
head screw.
DRYWALL GRID ADAPTER
INSTALLATION NOTES
NOTE:
The Cadiant™ Dynamic Skylight
is also suitable for installation in drywall
applications ONLY when mounted in the Cree
Lighting Drywall Grid Adapter Kit model
DGA22.
STEP 1:
Installation of the luminaire should follow the
instructions provided in the DGA kit with the
following exceptions:
• Drywall installation employing the DGA
kit is for single luminaire installations
ONLY.
• Ensure the luminaire is independently
secured to ceiling framing members by
mechanical means using the provided
tabs for Safety Wire Hangers. See
Figure 2.
2
RFM Module
Wiring Access Panel
(4) T-Bar Retention
Clips
(4) Tabs For Safety
Wire Hangers
Module Compartment
Sensor NEEDS TO BE
ORIENTED NORTH
(4) Tabs For Safety
Wire Hangers
Do not screw any
additional screws into
the side or top of the
luminaire.
3
Sensor
WEST
WEST
EAST`
EAST`
NORTH